Implementing 3-Switch XOR Ladder Logic with Internal Bit
Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.
Engineered for distributed machine-level monitoring, the Omron NS5-TQ10B-ECV2 serves as a centralized operator control interface within the premium NS-Series platform. This hardware terminal combines a vibrant 5.7-inch High-Luminance TFT Color LCD with robust communication capabilities, incorporating an integrated 10Base-T Ethernet port and dual serial transceivers. Operating on a standard 24 VDC input, the terminal is designed to withstand harsh factory environments, featuring an IP65f front-face rating and a resilient black protective bezel. With 60 MB of internal memory, it supports complex graphic representations, high-density alarm logging, and seamless CX-Designer configuration integration.
| Parameter | Specification Value |
|---|---|
| Manufacturer | Omron |
| Model Number | NS5-TQ10B-ECV2 |
| Display Type | 5.7-inch High-Luminance TFT Color LCD |
| Resolution | 320 x 240 pixels (QVGA) |
| Backlight | LED (non-replaceable, service life approx. 50,000 hours) |
| Input Voltage | 24 VDC (Acceptable range: 20.4 to 27.6 VDC) |
| Power Consumption | 15 W maximum |
| Onboard Ethernet | 1x RJ-45 Port (10Base-T) |
| Serial Communications | 2x RS-232C Ports (D-sub 9-pin female) |
| USB Interfaces | 1x USB Type B Slave (for programming download) |
| Internal Project Memory | 60 MB Flash Memory |
| Enclosure Bezel Color | Black |
| Protection Rating | IP65f (front panel, panel-mounted) |
| Operating Temperature | 0 to 50 degC |
| Shipping Weight (Calculated) | 1.85 kg |
| Package Dimensions (Calculated) | 245 x 195 x 110 mm |
| Port / Terminal Block | Physical Form | Signal Assignment & Pin Function |
|---|---|---|
| Serial Port A (CN1) | D-sub 9-pin Female | Host Link / NT Link RS-232C communication channel 1 |
| Serial Port B (CN2) | D-sub 9-pin Female | Host Link / NT Link RS-232C communication channel 2 |
| Ethernet | RJ-45 | 10Base-T network interface (FTP, screen data transfer, FINS communications) |
| USB (Slave) | USB Type B | Connection to CX-Designer programming PC for screen development and diagnostics |
| Power Input | M3 Screw Terminals | Pin 1: +24 VDC | Pin 2: 0 VDC | Pin 3: Functional Ground (FG) |
The "ECV2" revision represents a major evolutionary step over older NS5-TQ10B-V2 units. The critical distinction lies in the backlight design: the ECV2 employs an integrated solid-state LED configuration, whereas earlier legacy units utilized CCFL tubes driven by high-voltage internal inverters. Project databases generated for older NS5 versions can be converted to run on the ECV2 unit via CX-Designer; simply update the destination hardware designation inside the system properties before transferring. Be aware that color rendering profiles may differ slightly due to the shift from CCFL to LED emission spectrums.
Touch-screen matrix degradation is a common physical failure point if these terminals are installed in close proximity to radiant heat sources. While the unit functions up to 50 degC, prolonged internal temperatures exceeding 45 degC inside non-ventilated enclosures can lead to local delamination of the resistive overlay. For panels where ambient internal heat is a constant factor, we recommend installing low-draw convective air systems or cooling fans, maintaining a mandatory 100 mm clearing around the backplate air vents.
To prevent grounding-loop failures across serial pathways, ensure the functional ground terminal (FG) is tied back to the main cabinet star-ground point via a heavy-gauge (minimum 2 mm²) stranded green wire. When implementing RS-232C communication lines to CS/CJ-series PLCs, always utilize double-shielded twisted pairs and ground the cable shield on the PLC chassis side only. This layout successfully diverts high-frequency industrial noise away from the NS5 transceiver chips, avoiding intermittent "HMI Communication Timeouts" errors.
Global Express Shipping
Returns & Warranty

Engineered for distributed machine-level monitoring, the Omron NS5-TQ10B-ECV2 serves as a centralized operator control interface within the premium NS-Series platform. This hardware terminal combines a vibrant 5.7-inch High-Luminance TFT Color LCD with robust communication capabilities, incorporating an integrated 10Base-T Ethernet port and dual serial transceivers. Operating on a standard 24 VDC input, the terminal is designed to withstand harsh factory environments, featuring an IP65f front-face rating and a resilient black protective bezel. With 60 MB of internal memory, it supports complex graphic representations, high-density alarm logging, and seamless CX-Designer configuration integration.
| Parameter | Specification Value |
|---|---|
| Manufacturer | Omron |
| Model Number | NS5-TQ10B-ECV2 |
| Display Type | 5.7-inch High-Luminance TFT Color LCD |
| Resolution | 320 x 240 pixels (QVGA) |
| Backlight | LED (non-replaceable, service life approx. 50,000 hours) |
| Input Voltage | 24 VDC (Acceptable range: 20.4 to 27.6 VDC) |
| Power Consumption | 15 W maximum |
| Onboard Ethernet | 1x RJ-45 Port (10Base-T) |
| Serial Communications | 2x RS-232C Ports (D-sub 9-pin female) |
| USB Interfaces | 1x USB Type B Slave (for programming download) |
| Internal Project Memory | 60 MB Flash Memory |
| Enclosure Bezel Color | Black |
| Protection Rating | IP65f (front panel, panel-mounted) |
| Operating Temperature | 0 to 50 degC |
| Shipping Weight (Calculated) | 1.85 kg |
| Package Dimensions (Calculated) | 245 x 195 x 110 mm |
| Port / Terminal Block | Physical Form | Signal Assignment & Pin Function |
|---|---|---|
| Serial Port A (CN1) | D-sub 9-pin Female | Host Link / NT Link RS-232C communication channel 1 |
| Serial Port B (CN2) | D-sub 9-pin Female | Host Link / NT Link RS-232C communication channel 2 |
| Ethernet | RJ-45 | 10Base-T network interface (FTP, screen data transfer, FINS communications) |
| USB (Slave) | USB Type B | Connection to CX-Designer programming PC for screen development and diagnostics |
| Power Input | M3 Screw Terminals | Pin 1: +24 VDC | Pin 2: 0 VDC | Pin 3: Functional Ground (FG) |
The "ECV2" revision represents a major evolutionary step over older NS5-TQ10B-V2 units. The critical distinction lies in the backlight design: the ECV2 employs an integrated solid-state LED configuration, whereas earlier legacy units utilized CCFL tubes driven by high-voltage internal inverters. Project databases generated for older NS5 versions can be converted to run on the ECV2 unit via CX-Designer; simply update the destination hardware designation inside the system properties before transferring. Be aware that color rendering profiles may differ slightly due to the shift from CCFL to LED emission spectrums.
Touch-screen matrix degradation is a common physical failure point if these terminals are installed in close proximity to radiant heat sources. While the unit functions up to 50 degC, prolonged internal temperatures exceeding 45 degC inside non-ventilated enclosures can lead to local delamination of the resistive overlay. For panels where ambient internal heat is a constant factor, we recommend installing low-draw convective air systems or cooling fans, maintaining a mandatory 100 mm clearing around the backplate air vents.
To prevent grounding-loop failures across serial pathways, ensure the functional ground terminal (FG) is tied back to the main cabinet star-ground point via a heavy-gauge (minimum 2 mm²) stranded green wire. When implementing RS-232C communication lines to CS/CJ-series PLCs, always utilize double-shielded twisted pairs and ground the cable shield on the PLC chassis side only. This layout successfully diverts high-frequency industrial noise away from the NS5 transceiver chips, avoiding intermittent "HMI Communication Timeouts" errors.
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
Japan
|