Designed for high-density data acquisition within the Sysmac automation platform, the Omron NX-AD4603 provides high-speed, single-ended analog voltage monitoring across eight independent channels. This high-resolution module integrates into the Omron NX-series I/O system, offering seamless communication with Sysmac NJ/NX controllers or industrial couplers. By converting analog physical inputs to precise digital values under a Free-Run refreshing architecture, the Omron NX-AD4603 ensures reliable process tracking for complex industrial manufacturing environments.
| Parameter | Specification Value |
|---|---|
| Manufacturer | Omron |
| Model Number | NX-AD4603 |
| Number of Inputs | 8 points |
| Input Method | Single-ended input |
| Input Voltage Range | -10 to +10 VDC |
| Absolute Maximum Rating | +/-15 VDC |
| Resolution | 1/8000 (Full Scale) |
| Decimal Conversion Value | -4000 to 4000 (0 to 100%) |
| Overall Accuracy (at 25 degC) | 0.2% (Full Scale) |
| I/O Refreshing Method | Free-Run refreshing |
| Input Conversion Range | -5% to 105% (Full Scale) |
| Unit Weight | 0.070 kg (70 grams) |
| Shipping Weight (Calculated) | 0.35 kg |
The Omron NX-AD4603 is fully compatible with any NX-series EtherCAT Coupler Unit (such as the NX-ECC201/ECC202) and EtherNet/IP Coupler Units. It can also be directly mounted to the right of an NX1P2 CPU. Note that Sysmac Studio version 1.10 or higher is required for complete hardware configuration and calibration. If differential voltage inputs are required to isolate electrical signals across distant field sensors, consider the 2-point differential NX-AD2603 or the 4-point NX-AD3603.
Because this module utilizes a single-ended input design, all eight channels share a common internal ground connection. If your field transmitters reside at significantly different ground potentials, this shared reference can introduce ground loop noise, affecting reading accuracy or causing drift. In systems where sensor grounds cannot be equalized, install external signal isolators or transition to isolated differential input modules.
To prevent electromagnetic interference (EMI) from distorting low-level analog signals, always route input wiring away from high-voltage motor cables and variable frequency drive (VFD) output paths. Use shielded, twisted-pair cabling for all analog inputs, and ground the shielding foil at a single, solid earth point near the PLC chassis. Ensure the sensor voltage does not exceed the absolute limit of +/-15 V, as sustained overvoltage will degrade the internal ADC multiplexer.
Align the guide connectors on the side of the NX-AD4603 with the adjacent NX unit on the DIN rail.
Slide the module onto the DIN rail until the slide locking mechanism engages with an audible click.
Strip field wiring to the specified length (8 to 10 mm) and insert directly into the screwless push-in connection terminals.
Power up the system bus and verify status via the LED indicators on the front face of the module.
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
Japan
|