Designed for high-density signal integration within the Sysmac automation architecture, the Omron NX-ID6142-6 delivers 32 high-speed digital DC input channels in a space-saving slice profile. This industrial module allows for flexible polarity configurations, interfacing seamlessly with both NPN and PNP sensor topologies. Engineered for synchronization with EtherCAT networks, it supports both Synchronous and Free-Run I/O refreshing modes to provide exact time-stamped inputs for high-performance machine control.

Features

  • High-density 32-point input configuration using a compact physical footprint.
  • Flexible wiring options compatible with both NPN and PNP field devices.
  • Fast ON/OFF response times exceeding 1 microsecond for precise signal capture.
  • Supports Synchronous I/O refreshing to eliminate jitter in fast-cycle applications.
  • Integrated Fujitsu multi-pin connector interface for organized, secure harness terminations.

Applications

  • High-speed packaging machinery and sorting systems.
  • Multi-axis pick-and-place assembly lines.
  • Semiconductor processing and electronics manufacturing equipment.
  • Automated material handling and synchronized conveyor control.

Technical Specifications

Parameter Specification Value
Manufacturer Omron
Model Number NX-ID6142-6
Product Series NX-series Digital I/O Unit
Input Type DC Input (NPN/PNP Compatible)
Number of Points 32 Points
Rated Input Voltage 24 VDC
ON/OFF Response Time Exceeds 1 microsecond
I/O Refreshing Method Free-Run refreshing or Synchronous I/O refreshing
External Connection Fujitsu Connector
Module Width 30 mm (3 cm)
Module Dimensions 100 mm Height x 30 mm Width x 71 mm Depth
Net Weight 0.09 kg
Shipping Weight (Calculated) 1.50 kg (including protective packaging)

Empirical Engineering Insights

Alternative Models & Compatibility

The NX-ID6142-6 utilizes a Fujitsu connector interface, which differs significantly from screwless clamp models. Ensure that matching pre-wired cables (such as Omron's XY3B series) or compatible connector terminal blocks are specified during panel design. It is fully backward compatible with NX-series bus couplers running standard EtherCAT or EtherNet/IP interfaces.

Application Pitfalls & Engineering Notes

Because this is a high-density 32-point unit, thermal accumulation can occur within closed wire ducts if all 32 inputs are continuously active at 24 VDC. Maintain adequate cooling clearances as outlined in the Sysmac NX-series user manual, and verify that the auxiliary current limit of your internal bus coupler is not exceeded when multiple high-density input blocks are powered from the same segment.

Commissioning & Wiring Tips

To minimize electrical noise in high-speed applications, always use shielded, twisted-pair cabling for the Fujitsu connector. Ground the cable shields at a single point on the panel's common functional ground bar. Ensure the 24 VDC external power supply has adequate ripple filtering to prevent timing jitter during synchronous cycles.

Installation Guidelines

CRITICAL SAFETY WARNING

De-energize all primary, secondary, and field-side power sources before inserting or removing the module from the DIN rail assembly. Working on live backplanes risks permanent damage to the internal ASIC and can corrupt the EtherCAT network configuration.

1
Align the slide guides on the side of the NX-ID6142-6 with the adjacent NX unit on the DIN rail.
2
Slide the unit straight down onto the DIN rail until the locking hook clicks firmly into place.
3
Securely lock the unit using the end plates on both ends of the modular assembly to prevent lateral movement.
4
Insert the pre-wired Fujitsu connector cable assembly, tightening any mechanical retaining screws to prevent vibration-induced loosening.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What connector type is required for wiring the Omron NX-ID6142-6?
The module uses a multi-pin Fujitsu connector for field wiring. Standard pre-assembled cables or discrete pin connectors are required for external terminations.
Can I mix NPN and PNP inputs on the NX-ID6142-6?
Yes. The module is compatible with both NPN and PNP configurations. The internal circuitry supports bi-directional current flow depending on your common terminal layout.
Does this module support synchronous EtherCAT cycles?
Yes. The NX-ID6142-6 supports Synchronous I/O refreshing, which aligns input sampling directly with the EtherCAT communications cycle for highly synchronized applications.
How do I handle thermal dissipation with 32 points active?
Ensure proper DIN rail spacing and vertical orientation inside the enclosure to facilitate passive cooling. Verify that your total current draw matches the limits of your NX-series power supply unit.
Reviews

NX-ID6142-6

Stock & lead time on request

Call
1 of 1

Omron NX-ID6142-6 NX-series Digital Input Unit

Only 5 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: NX-ID6142-6

  • Country of origin:Japan

  • Product Type: Digital Input Modules

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Dimensions: 3 cm x 7.1 cm x 10 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for high-density signal integration within the Sysmac automation architecture, the Omron NX-ID6142-6 delivers 32 high-speed digital DC input channels in a space-saving slice profile. This industrial module allows for flexible polarity configurations, interfacing seamlessly with both NPN and PNP sensor topologies. Engineered for synchronization with EtherCAT networks, it supports both Synchronous and Free-Run I/O refreshing modes to provide exact time-stamped inputs for high-performance machine control.

Features

  • High-density 32-point input configuration using a compact physical footprint.
  • Flexible wiring options compatible with both NPN and PNP field devices.
  • Fast ON/OFF response times exceeding 1 microsecond for precise signal capture.
  • Supports Synchronous I/O refreshing to eliminate jitter in fast-cycle applications.
  • Integrated Fujitsu multi-pin connector interface for organized, secure harness terminations.

Applications

  • High-speed packaging machinery and sorting systems.
  • Multi-axis pick-and-place assembly lines.
  • Semiconductor processing and electronics manufacturing equipment.
  • Automated material handling and synchronized conveyor control.

Technical Specifications

Parameter Specification Value
Manufacturer Omron
Model Number NX-ID6142-6
Product Series NX-series Digital I/O Unit
Input Type DC Input (NPN/PNP Compatible)
Number of Points 32 Points
Rated Input Voltage 24 VDC
ON/OFF Response Time Exceeds 1 microsecond
I/O Refreshing Method Free-Run refreshing or Synchronous I/O refreshing
External Connection Fujitsu Connector
Module Width 30 mm (3 cm)
Module Dimensions 100 mm Height x 30 mm Width x 71 mm Depth
Net Weight 0.09 kg
Shipping Weight (Calculated) 1.50 kg (including protective packaging)

Empirical Engineering Insights

Alternative Models & Compatibility

The NX-ID6142-6 utilizes a Fujitsu connector interface, which differs significantly from screwless clamp models. Ensure that matching pre-wired cables (such as Omron's XY3B series) or compatible connector terminal blocks are specified during panel design. It is fully backward compatible with NX-series bus couplers running standard EtherCAT or EtherNet/IP interfaces.

Application Pitfalls & Engineering Notes

Because this is a high-density 32-point unit, thermal accumulation can occur within closed wire ducts if all 32 inputs are continuously active at 24 VDC. Maintain adequate cooling clearances as outlined in the Sysmac NX-series user manual, and verify that the auxiliary current limit of your internal bus coupler is not exceeded when multiple high-density input blocks are powered from the same segment.

Commissioning & Wiring Tips

To minimize electrical noise in high-speed applications, always use shielded, twisted-pair cabling for the Fujitsu connector. Ground the cable shields at a single point on the panel's common functional ground bar. Ensure the 24 VDC external power supply has adequate ripple filtering to prevent timing jitter during synchronous cycles.

Installation Guidelines

CRITICAL SAFETY WARNING

De-energize all primary, secondary, and field-side power sources before inserting or removing the module from the DIN rail assembly. Working on live backplanes risks permanent damage to the internal ASIC and can corrupt the EtherCAT network configuration.

1
Align the slide guides on the side of the NX-ID6142-6 with the adjacent NX unit on the DIN rail.
2
Slide the unit straight down onto the DIN rail until the locking hook clicks firmly into place.
3
Securely lock the unit using the end plates on both ends of the modular assembly to prevent lateral movement.
4
Insert the pre-wired Fujitsu connector cable assembly, tightening any mechanical retaining screws to prevent vibration-induced loosening.

What connector type is required for wiring the Omron NX-ID6142-6?

The module uses a multi-pin Fujitsu connector for field wiring. Standard pre-assembled cables or discrete pin connectors are required for external terminations.

Can I mix NPN and PNP inputs on the NX-ID6142-6?

Yes. The module is compatible with both NPN and PNP configurations. The internal circuitry supports bi-directional current flow depending on your common terminal layout.

Does this module support synchronous EtherCAT cycles?

Yes. The NX-ID6142-6 supports Synchronous I/O refreshing, which aligns input sampling directly with the EtherCAT communications cycle for highly synchronized applications.

How do I handle thermal dissipation with 32 points active?

Ensure proper DIN rail spacing and vertical orientation inside the enclosure to facilitate passive cooling. Verify that your total current draw matches the limits of your NX-series power supply unit.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...