Description
Designed for seamless integration within high-speed Sysmac automation platforms, the NX-OD5256-1 serves as a high-density digital output module featuring 16 transistor outputs. This unit enables precise control over field actuators by delivering reliable switching performance synchronized with the machine controller's execution cycle. Operating on a 24 VDC rated voltage, the module utilizes PNP (source) logic and features built-in load short-circuit protection to safeguard system electronics against field-side electrical faults.
The unit supports advanced synchronization capabilities, allowing for both Free-Run and Synchronous I/O refreshing. Field connections are secured via a rugged, detachable M3 screw terminal block, which facilitates easy installation and maintenance. Designed for mounting on a standard DIN rail, this module connects directly to NX-series Bus Couplers for EtherCAT or EtherNet/IP, making it highly compatible with modern distributed control architectures.
Features
- Provides 16 digital output points in a compact form factor.
- Utilizes PNP (source) output logic with a rated voltage of 24 VDC.
- Features integrated load short-circuit protection for system safety.
- Supports Synchronous I/O refreshing and Free-Run refreshing modes.
- Equipped with a detachable M3 screw terminal block for reliable physical wiring.
- Simplifies configuration and troubleshooting via Sysmac Studio software.
Applications
- Packaging and labeling machinery control
- Automated assembly and material handling systems
- Water treatment and environmental control panels
- Pneumatic and hydraulic valve manifold actuation
- General factory automation and distributed I/O systems
Technical Specifications
| Parameter |
Specification |
| Manufacturer |
Omron |
| Part Number/Model |
NX-OD5256-1 |
| Series |
NX-series Digital I/O Unit |
| Output Type |
Transistor Output (PNP/Source) |
| Number of Outputs |
16 points |
| Rated Voltage |
24 VDC |
| Maximum Load Current |
0.5 A per point |
| I/O Refreshing Method |
Free-Run refreshing, Synchronous I/O refreshing |
| Short-Circuit Protection |
Yes (Load short-circuit protection) |
| External Connection Terminals |
M3 screw terminal block |
| Dimensions (W x H x D) |
30 mm x 100 mm x 71 mm |
| Weight |
0.125 kg |
Installation Guidelines
Ensure the following engineering practices are observed during the installation of the module:
-
Mounting: Mount the module securely onto a 35 mm DIN rail inside a protective industrial enclosure. Verify the DIN rail is properly grounded.
-
Wiring: Turn off all power supplies before connecting or disconnecting the M3 screw terminal block to prevent electrical shock or equipment damage.
-
Heat Dissipation: Maintain recommended clearances above and below the NX-series unit stack to ensure natural convection cooling. Do not block the ventilation holes.
-
Shielding and Noise: Route DC control lines separate from high-voltage AC power lines to minimize electromagnetic interference.
Compliance and Certifications
- CE Mark
- UL Listed (cULus)