Omron

Omron NX-PG0242-5 NX Series Pulse Output Unit

SKU NX-PG0242-5

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Omron

  • Product No.: NX-PG0242-5

  • Country of origin:Japan

  • Product Type: Pulse Output Units

  • Payment: T/T, Western Union

  • Weight: 110g

  • Dimensions: 30 mm x 100 mm x 71 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

High-performance motion control applications require precise pulse train generation, which is delivered by the NX-PG0242-5 motion control module. Engineered as a high-density, 2-channel pulse output unit for the Omron Sysmac platform, this module provides line driver outputs compatible with PNP-type external interfaces. It integrates seamlessly into the NX-series I/O system, enabling synchronized open-loop control of servo drives and stepper motor drives.

Utilizing synchronous I/O refreshing or task period prioritized refreshing, this unit ensures minimal jitter and deterministic execution of motion profiles. Connection is consolidated through a high-density MIL connector interface, reducing panel footprint and wiring complexity while maintaining high signal integrity for high-speed transmission.

Features

  • Two independent pulse output channels for multi-axis positioning.
  • Support for synchronous I/O refreshing to coordinate motion tasks directly with the controller CPU cycle.
  • Multiple pulse output modes including Forward/Reverse direction, Pulse + Direction, and Phase Differential (x1, x2, or x4 multiplication).
  • Consolidated wiring via a 34-terminal MIL connector interface.
  • Integrated inputs and outputs (5 inputs and 5 outputs per channel) for limit switches, origin sensors, and auxiliary controls.

Applications

  • Packaging machinery and rotary indexing tables.
  • Semiconductor manufacturing and wafer handling systems.
  • High-speed pick-and-place gantry robots.
  • Multi-axis stepper and servo drive synchronization.

Technical Specifications

ManufacturerPart Number / ModelSeriesModule TypeNumber of ChannelsControl MethodPulse Output FormVelocity Control RangePosition Control RangeInputs per ChannelOutputs per ChannelI/O Refreshing MethodExternal Connection TypeCurrent Consumption (I/O Power Supply)Line Driver Cable LengthAuxiliary I/O Cable LengthDimensions (W x H x D)Weight
Omron
NX-PG0242-5
NX Series
Pulse Output Unit (Line Driver Output, PNP type)
2
Open-loop control through pulse string output
Line driver output
1 to 4,000,000 pps
-2,147,483,648 to 2,147,483,647 pulses
5 external inputs
5 (1 forward pulse, 1 reverse pulse, 3 external outputs)
Synchronous I/O refreshing or task period prioritized refreshing
MIL connector (34 terminals x 1)
50 mA maximum
10 m maximum
3 m maximum
30 mm x 100 mm x 71 mm
0.11 kg

Installation Guidelines

  • Mounting: Mount the module securely onto standard 35 mm DIN rail within the NX-series bus expansion assembly.
  • Shielding: Use shielded twisted-pair (STP) cabling for all line driver pulse outputs to minimize electromagnetic interference (EMI).
  • Cable Lengths: Ensure line driver output cables do not exceed 10 meters, and standard I/O sensor cables are kept under 3 meters.
  • Grounding: Ensure the DIN rail is connected to a protective ground (PE) terminal to maintain proper noise immunity.

FAQ

What is the primary function of the Omron NX-PG0242-5?

The NX-PG0242-5 is a 2-channel motion control unit that generates high-speed pulse train outputs to drive stepper motor drives or servo drives in an open-loop configuration.

What kind of output stage does this unit use?

It utilizes a line driver output stage designed for high noise immunity and supports PNP-type external interfaces.

How are connections wired to the NX-PG0242-5?

All channel inputs, pulse outputs, and auxiliary outputs are consolidated into a single 34-terminal MIL connector.

What is the maximum cable length supported for the pulse outputs?

The line driver outputs support a maximum cable length of 10 meters, while other standard I/O lines are limited to 3 meters.

Which synchronization modes are supported by this module?

It supports synchronous I/O refreshing, which aligns I/O operations with the controller's primary CPU cycle, and task period prioritized refreshing.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Technical knowledge

Designing Power and Communication Redundancy

Design control-system redundancy by mapping shared dependencies, separating power and network paths, defining failover behavior, exposing degraded operation, and proof-testing every tolerated fault.

Troubleshooting Industrial Control Cabinets Systematically

A structured control-cabinet troubleshooting method covering safe work, drawings, power paths, branch protection, DC supplies, return circuits, PLC outputs, fault records and repair verification.

Measuring Voltage in Industrial Control Circuits

A practical voltage-testing guide for industrial control panels, covering reference points, meter selection, live-dead-live checks, voltage drop, ghost voltage, stored energy and intermittent faults.

Building a Verifiable Lockout Tagout Procedure

A practical lockout tagout guide covering hazardous-energy identification, isolation, stored-energy control, verification, group work, temporary testing, restoration, inspections and audits.

Designing Compressed-Air Preparation at the Machine

A field guide to point-of-use compressed-air preparation covering filters, regulators, drains, dryers, lubrication, pressure loss, isolation, monitoring, commissioning and leak testing.

Selecting Pneumatic Valve Actuation and Safe States

A practical guide to manual, pilot and solenoid pneumatic valves, covering port functions, monostable and bistable behavior, PLC outputs, safe states, commissioning and fault diagnosis.