Omron NX-SID800 | Omron | NX-series Safety Input Unit
SKU NX-SID800
In stock
No reviews
12-month warranty
Free returns within 30 days
Manufacturer:
Omron
Product No.:
NX-SID800
Country of origin:Japan
Product Type:
NX I/O Bus
Payment:
T/T, Western Union
Weight:
1000g
Dimensions:
12 × 100 × 71 mm (W × H × D)
Shipping port:
Xiamen
Warranty:
12 months
Description
The NX-SID800 is a specialized Safety Input Unit within the Omron NX-series I/O system, engineered to interface with safety-critical devices in industrial automation. This module provides 8 safety input points and 2 test output points, utilizing a PNP (sinking) input configuration. Designed for robust safety applications, the unit operates on a 24 VDC rated input voltage and ensures high-integrity monitoring of emergency stops, light curtains, or safety switches. It features a compact 12 mm wide housing and uses a screwless clamping terminal block for reliable, vibration-resistant electrical connections, making it an essential component for distributed safety control architectures.
Features
Safety Interface: 8 safety input points and 2 test output points
Input Configuration: PNP (sinking) inputs with standardized 24 VDC operation
Reliability: Built-in test outputs allow for cross-circuit and short-circuit detection in safety sensors
Compact Design: Slim 12 mm wide module for high-density I/O panels
Efficiency: Low power consumption (0.75 W max)
Applications
Emergency stop monitoring
Safety door switch integration
Light curtain and safety sensor data acquisition
Distributed safety control systems
Technical Specifications
Parameter
Specification
Manufacturer
Omron
Model
NX-SID800
Product Type
Safety Input Unit
Safety Input Points
8
Test Output Points
2
Rated Input Voltage
24 VDC
Connection Type
Screwless clamping (16 terminals)
Refreshing Method
Free-Run refreshing
Dimensions
12 mm x 100 mm x 71 mm
Weight
70 g
Installation Guidelines
Mounting: The NX-SID800 mounts directly to the NX-series I/O bus on a standard DIN rail. Ensure the module is securely locked into the bus connector.
Wiring: Utilize the 16-terminal screwless clamping block. Ensure wires are stripped to the required length for optimal contact and stress-free insertion.
Safety Configuration: Safety inputs must be configured in the master controller software to match the safety device requirements.
Test Outputs: Utilize the 2 test output points to perform discrepancy monitoring and detect short-circuits in the input wiring, which is a requirement for meeting higher safety performance levels.
FAQ
What is the primary function of the test output points on the NX-SID800?
The test outputs are used to perform diagnostic checks on the safety inputs, such as detecting cross-circuits, short-circuits, or open-circuit faults in the safety wiring.
Does the NX-SID800 support standard I/O?
The NX-SID800 is specifically designed as a safety unit for monitoring safety-rated inputs. It is not intended for standard general-purpose I/O applications.
What is the physical width of this safety module?
The module has a compact width of 12 mm, allowing for high-density mounting in the control panel.
Learn how Mitsubishi FX PLC STL and RET instructions structure conveyor and pneumatic sequences, with practical state design, transition logic, timeouts, diagnostics, and safe restart boundaries.
A practical guide to selecting, wiring and diagnosing DIN-style valve connectors, including form identification, coil voltage, suppression, polarity, sealing, release-time effects and commissioning...
A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...