Description
Precision thermal regulation within high-speed industrial environments is achieved using the Omron NX-TC3408, a multi-channel temperature control module designed for the Sysmac automation platform. Operating on the NX-series I/O system backplane, this unit provides 4 independent control loops with integrated thermocouple and resistance thermometer (RTD) inputs. It leverages 4 high-resolution analog outputs (0 to 20 mA or 4 to 20 mA) to deliver smooth, variable manipulated variable (MV) outputs for precise heat or cool control applications.
The unit features a rapid 50 ms conversion time per unit, ensuring fast response times in dynamic thermal systems. To simplify field installation and reduce panel assembly time, the NX-TC3408 is built with screwless Push-in Plus terminal blocks across two detachable connectors. This allows pre-wiring and simple swap-out maintenance, minimizing system downtime.
Features
- Four independent control loops for multi-zone thermal management.
- Universal temperature inputs supporting major thermocouples and Pt100/JPt100 RTDs.
- Four 14-bit analog current outputs configurable for 4 to 20 mA or 0 to 20 mA operation.
- Fast conversion rate of 50 ms per unit for high-speed tracking.
- Dual-zone control capabilities supporting both heating and cooling functions.
- Push-in Plus terminal connections for reliable, tool-free wiring.
- Detachable front I/O connector blocks for fast maintenance and installation.
- Seamless integration into EtherCAT or EtherNet/IP networks via NX-series coupler units.
Applications
- Plastic extrusion and injection molding machine barrel heating zones.
- Packaging machines requiring precise heat sealing bar regulation.
- Industrial ovens, drying chambers, and heat treatment furnaces.
- Semiconductor manufacturing equipment thermal control.
- Food processing and pasteurization temperature monitoring.
Technical Specifications
| Manufacturer |
Omron |
| Model/Part Number |
NX-TC3408 |
| Series |
NX-series I/O System |
| Control Loops |
4 loops |
| Temperature Input Types |
Thermocouple (B, C (WRe5-26), E, J, K, L, N, P (PLII), R, S, T, U), RTD (Pt100, JPt100) |
| Analog Outputs |
4 current outputs (0 to 20 mA, 4 to 20 mA) |
| Analog Output Resolution |
14-bit (1:10000) |
| Conversion Time |
50 ms/unit |
| Control Mode |
Heat or Cool control |
| I/O Connection Type |
Push-in Plus terminals |
| Number of Connectors |
2 detachable I/O connectors |
| Enclosure Rating |
IP20 |
| Width |
24 mm |
| Height |
100 mm |
| Depth |
80 mm |
| Weight |
140 g (unpacked) |
Connections and Interfaces
The unit features dual-tiered Push-in Plus terminal blocks. Connections are split across two independent, detachable terminal blocks to organize sensory input and control output wiring safely:
| Terminal Section |
Function Description |
| Sensor Inputs |
Dedicated connection points for 4-channel Thermocouple or Pt100/JPt100 RTD leads. Fully isolated input circuits. |
| Analog Outputs |
4-channel current output terminals (0 to 20 mA / 4 to 20 mA) routed to control elements like solid-state relays or modulating valves. |
| NX Bus Connection |
Direct backplane interface to adjacent NX-series I/O modules and the bus coupler/controller unit. |
Installation Guidelines
- Mount the module securely onto a standard 35 mm DIN rail within a dust-free, dry control cabinet.
- Ensure that power to the NX-series bus coupler or controller is switched off before mounting or removing the module.
- To prevent electromagnetic interference (EMI) on sensitive RTD or thermocouple signals, route temperature sensor lines away from high-voltage motor and drive cabling.
- Maintain a minimum of 10 mm clearance around the module ventilation paths to prevent heat buildup.