Designed for precise thermal data acquisition in automated industrial environments, the NX-TS2201 delivers high-resolution temperature monitoring within the Omron Sysmac platform. This high-density temperature input unit supports up to two resistance thermometer (RTD) input points, processing signals from Pt100 and Pt1000 three-wire sensors. Utilizing a fast conversion cycle of 250 ms per unit and achieving a thermal resolution of 0.1 degC, it ensures stable and accurate process variables for critical control loops.
The module is built on the NX-series I/O platform, interfacing directly with NX-series CPU Units or Communication Couplers over EtherCAT or EtherNet/IP networks. To ensure high signal integrity in noisy electrical environments, the unit incorporates comprehensive galvanic isolation between individual inputs and the internal NX bus, alongside channel-to-channel isolation. Connection to field sensors is simplified through a high-reliability, 16-terminal screwless clamping terminal block.
| Manufacturer | Omron |
| Part Number/Model | NX-TS2201 |
| Series | NX Series I/O |
| Input Type | Resistance Thermometer (Pt100/Pt1000, 3-wire) |
| Number of Inputs | 2 points |
| Conversion Time | 250 ms per Unit |
| Resolution | 0.1 degC max. |
| I/O Refreshing Method | Free-Run refreshing |
| Input Detection Current | Approx. 0.25 mA |
| Conductor Resistance Effect | 0.06 degC/Ohm max. (up to 20 Ohm max.) |
| External Connections | 16-terminal screwless clamping block |
| Indicators | TS status indicator |
| Isolation Method | Between Input and NX Bus: Transformer (Power), Photocoupler (Signal) Between Inputs: Transformer (Power), Photocoupler (Signal) |
| Insulation Resistance | 20 MOhm min. between isolated circuits (at 100 VDC) |
| Dielectric Strength | 510 VAC between isolated circuits for 1 minute (leakage current 5 mA max.) |
| Power Consumption (CPU Connection) | 1.25 W max. (when connected to a CPU Unit or Communication Control Unit) |
| Power Consumption (Coupler Connection) | 0.90 W max. (when connected to a Communications Coupler Unit) |
| Dimensions | 12 (W) x 100 (H) x 71 (D) mm |
| Weight | 0.07 kg |
Global Express Shipping
Returns & Warranty

Designed for precise thermal data acquisition in automated industrial environments, the NX-TS2201 delivers high-resolution temperature monitoring within the Omron Sysmac platform. This high-density temperature input unit supports up to two resistance thermometer (RTD) input points, processing signals from Pt100 and Pt1000 three-wire sensors. Utilizing a fast conversion cycle of 250 ms per unit and achieving a thermal resolution of 0.1 degC, it ensures stable and accurate process variables for critical control loops.
The module is built on the NX-series I/O platform, interfacing directly with NX-series CPU Units or Communication Couplers over EtherCAT or EtherNet/IP networks. To ensure high signal integrity in noisy electrical environments, the unit incorporates comprehensive galvanic isolation between individual inputs and the internal NX bus, alongside channel-to-channel isolation. Connection to field sensors is simplified through a high-reliability, 16-terminal screwless clamping terminal block.
| Manufacturer | Omron |
| Part Number/Model | NX-TS2201 |
| Series | NX Series I/O |
| Input Type | Resistance Thermometer (Pt100/Pt1000, 3-wire) |
| Number of Inputs | 2 points |
| Conversion Time | 250 ms per Unit |
| Resolution | 0.1 degC max. |
| I/O Refreshing Method | Free-Run refreshing |
| Input Detection Current | Approx. 0.25 mA |
| Conductor Resistance Effect | 0.06 degC/Ohm max. (up to 20 Ohm max.) |
| External Connections | 16-terminal screwless clamping block |
| Indicators | TS status indicator |
| Isolation Method | Between Input and NX Bus: Transformer (Power), Photocoupler (Signal) Between Inputs: Transformer (Power), Photocoupler (Signal) |
| Insulation Resistance | 20 MOhm min. between isolated circuits (at 100 VDC) |
| Dielectric Strength | 510 VAC between isolated circuits for 1 minute (leakage current 5 mA max.) |
| Power Consumption (CPU Connection) | 1.25 W max. (when connected to a CPU Unit or Communication Control Unit) |
| Power Consumption (Coupler Connection) | 0.90 W max. (when connected to a Communications Coupler Unit) |
| Dimensions | 12 (W) x 100 (H) x 71 (D) mm |
| Weight | 0.07 kg |