Omron

Omron NX701-1620 NX7 Motion Controller

SKU NX701-1620

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Omron
  • Product No.: NX701-1620
  • Origin Japan
  • Product Type: Motion Controllers
  • Payment: T/T, Western Union
  • Weight: 0.88 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

Delivering rapid processing capabilities for high-performance automation, the Omron NX701-1620 provides execution of complex motion and database logging algorithms directly within the controller core. This heavy-duty system controller acts as the central command unit for large-scale production facilities, synchronizing high-speed sequence programs and multi-axis trajectory profiles. By integrating native direct SQL database connectivity and an embedded OPC-UA server, it bridges the gap between the plant floor and IT-level enterprise systems without requiring gateway PCs or specialized middleware.

Features

  • Direct synchronization of up to 128 physical motion axes for complex electronic gearing and camming applications.
  • Ultra-fast cycle execution with a primary task cycle time of 0.125 ms.
  • Embedded DB client function enables real-time logging to Microsoft SQL, Oracle, MySQL, PostgreSQL, and Firebird servers.
  • Built-in industrial network protocols including EtherCAT Master and dual EtherNet/IP ports.
  • Massive memory allocation with 80 MB program capacity and 260 MB variables memory.

Applications

  • High-speed rotary packaging and form-fill-seal lines.
  • Multi-axis robotic handling and assembly cells.
  • Traceability-heavy pharmaceutical or automotive assembly lines requiring direct database tracking.
  • High-precision semiconductor fabrication tool automation.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number NX701-1620
Controller Series Sysmac NX7
Task Cycle Time 0.125 ms
Program Memory 80 MB
Variables Memory 260 MB
Max. Controlled Axes 128 Synchronous Axes
Communication Ports EtherCAT (Master), EtherNet/IP (2 Ports), Ethernet TCP/IP
Local I/O Bus NX I/O Bus System
Net Weight 0.88 kg
Shipping Weight 3.00 kg

Connections and Interfaces

Interface Port Functional Protocol Assignment
Port 1 (EtherNet/IP) Host communications, HMI interface, Tag Data Link networking, Sysmac Studio tool interface.
Port 2 (EtherNet/IP) Secondary industrial network ring, direct SQL client execution, or OPC-UA server communications.
Port 3 (EtherCAT) Deterministic servo drive control, distributed I/O couplers, high-speed remote nodes.
SD Card Slot Logging spools, memory card storage, OS firmware updates, and system recovery.

Empirical Engineering Insights

Alternative Models & Compatibility

The NX701-1620 is configured within the Sysmac Studio platform. It replaces smaller controllers like the NX701-1600 (which is limited to 64 axes) in scenarios where mechanical expansions demand increased servo synchronization. Ensure that all program files are recompiled in Sysmac Studio version 1.10 or higher when converting code from older NX-series platforms.

Application Pitfalls & Engineering Notes

When utilizing the direct SQL connection feature, ensure your database spooling configuration is active. If the destination database server goes offline, the controller utilizes internal memory blocks as a buffer. If the outage exceeds the buffer capacity, data overwrite warnings occur. Always set up appropriate diagnostic alarms to monitor SQL transaction queues.

Commissioning & Wiring Tips

High-density multi-axis EtherCAT loops require high-quality STP Cat5e (or better) industrial Ethernet cables. Poorly shielded or loose cabling will introduce microsecond jitter, resulting in intermittent packet loss and subsequent controller axis synchronization faults. Route network communication wires away from high-power servo motor cables.

Installation Guidelines

CRITICAL WARNING: De-energize all primary and auxiliary 24 VDC power supplies before mounting, demounting, or wiring the controller. Failure to disconnect power during installation can lead to internal circuit damage, arc-flashes, or unexpected equipment movement.
1
Align the back DIN rail hook of the controller onto the standard 35 mm DIN track, pushing until it clicks securely into place.
2
Securely connect the functional ground wire to a low-impedance grounding point, ensuring adequate noise immunity.
3
Wire the designated 24 VDC power supply to the unit's supply terminals, verifying correct polarity before applying power.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What databases can the NX701-1620 write to directly?
The controller natively supports direct connections to Microsoft SQL Server, Oracle Database, MySQL, PostgreSQL, and Firebird. No intermediate PC or gateway software is required.
Can this unit run without a local SD card?
Yes, standard PLC sequence and motion logic will execute from non-volatile memory, but an SD memory card is required to use the DB connection spooling buffer and system backup tools.
What software is used to program the NX701-1620?
Configuration, programming, and system tuning are performed exclusively via Omron Sysmac Studio software, utilizing the integrated IEC 61131-3 development environment.
Reviews

NX701-1620

Stock & lead time on request

Call
1 of 1

Omron NX701-1620 NX7 Motion Controller

Only 2 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: NX701-1620

  • Country of origin:Japan

  • Product Type: Motion Controllers

  • Payment: T/T, Western Union

  • Weight: 880g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Delivering rapid processing capabilities for high-performance automation, the Omron NX701-1620 provides execution of complex motion and database logging algorithms directly within the controller core. This heavy-duty system controller acts as the central command unit for large-scale production facilities, synchronizing high-speed sequence programs and multi-axis trajectory profiles. By integrating native direct SQL database connectivity and an embedded OPC-UA server, it bridges the gap between the plant floor and IT-level enterprise systems without requiring gateway PCs or specialized middleware.

Features

  • Direct synchronization of up to 128 physical motion axes for complex electronic gearing and camming applications.
  • Ultra-fast cycle execution with a primary task cycle time of 0.125 ms.
  • Embedded DB client function enables real-time logging to Microsoft SQL, Oracle, MySQL, PostgreSQL, and Firebird servers.
  • Built-in industrial network protocols including EtherCAT Master and dual EtherNet/IP ports.
  • Massive memory allocation with 80 MB program capacity and 260 MB variables memory.

Applications

  • High-speed rotary packaging and form-fill-seal lines.
  • Multi-axis robotic handling and assembly cells.
  • Traceability-heavy pharmaceutical or automotive assembly lines requiring direct database tracking.
  • High-precision semiconductor fabrication tool automation.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number NX701-1620
Controller Series Sysmac NX7
Task Cycle Time 0.125 ms
Program Memory 80 MB
Variables Memory 260 MB
Max. Controlled Axes 128 Synchronous Axes
Communication Ports EtherCAT (Master), EtherNet/IP (2 Ports), Ethernet TCP/IP
Local I/O Bus NX I/O Bus System
Net Weight 0.88 kg
Shipping Weight 3.00 kg

Connections and Interfaces

Interface Port Functional Protocol Assignment
Port 1 (EtherNet/IP) Host communications, HMI interface, Tag Data Link networking, Sysmac Studio tool interface.
Port 2 (EtherNet/IP) Secondary industrial network ring, direct SQL client execution, or OPC-UA server communications.
Port 3 (EtherCAT) Deterministic servo drive control, distributed I/O couplers, high-speed remote nodes.
SD Card Slot Logging spools, memory card storage, OS firmware updates, and system recovery.

Empirical Engineering Insights

Alternative Models & Compatibility

The NX701-1620 is configured within the Sysmac Studio platform. It replaces smaller controllers like the NX701-1600 (which is limited to 64 axes) in scenarios where mechanical expansions demand increased servo synchronization. Ensure that all program files are recompiled in Sysmac Studio version 1.10 or higher when converting code from older NX-series platforms.

Application Pitfalls & Engineering Notes

When utilizing the direct SQL connection feature, ensure your database spooling configuration is active. If the destination database server goes offline, the controller utilizes internal memory blocks as a buffer. If the outage exceeds the buffer capacity, data overwrite warnings occur. Always set up appropriate diagnostic alarms to monitor SQL transaction queues.

Commissioning & Wiring Tips

High-density multi-axis EtherCAT loops require high-quality STP Cat5e (or better) industrial Ethernet cables. Poorly shielded or loose cabling will introduce microsecond jitter, resulting in intermittent packet loss and subsequent controller axis synchronization faults. Route network communication wires away from high-power servo motor cables.

Installation Guidelines

CRITICAL WARNING: De-energize all primary and auxiliary 24 VDC power supplies before mounting, demounting, or wiring the controller. Failure to disconnect power during installation can lead to internal circuit damage, arc-flashes, or unexpected equipment movement.
1
Align the back DIN rail hook of the controller onto the standard 35 mm DIN track, pushing until it clicks securely into place.
2
Securely connect the functional ground wire to a low-impedance grounding point, ensuring adequate noise immunity.
3
Wire the designated 24 VDC power supply to the unit's supply terminals, verifying correct polarity before applying power.

What databases can the NX701-1620 write to directly?

The controller natively supports direct connections to Microsoft SQL Server, Oracle Database, MySQL, PostgreSQL, and Firebird. No intermediate PC or gateway software is required.

Can this unit run without a local SD card?

Yes, standard PLC sequence and motion logic will execute from non-volatile memory, but an SD memory card is required to use the DB connection spooling buffer and system backup tools.

What software is used to program the NX701-1620?

Configuration, programming, and system tuning are performed exclusively via Omron Sysmac Studio software, utilizing the integrated IEC 61131-3 development environment.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...