Description

Engineered for reliable network performance at the field level, the W4S1-03B industrial switching hub provides robust Ethernet connectivity in demanding factory automation environments. This compact, 3-port unmanaged switch supports fast Ethernet speeds (10BASE-T/100BASE-TX) and is optimized for direct integration with PLCs, HMIs, and distributed I/O systems.

The device ensures stable packet transmission using an internal 80 KB buffer capacity and accommodates up to 2,000 MAC address entries. Designed with industrial-grade resilience, it features a low power consumption profile and comes supplied with a dedicated power supply connector for secure 24 VDC wiring.

Features

  • Compact 3-port layout designed for high-density space-constrained control panels.
  • Full compatibility with IEEE 802.3 (10BASE-T) and IEEE 802.3u (100BASE-TX) Ethernet standards.
  • Integrated 80 KB packet buffer to minimize data frame loss during peak traffic.
  • Support for up to 2,000 MAC addresses.
  • Supplied with a dedicated terminal connector for stable power distribution.

Applications

  • Factory automation and control systems networking.
  • Fieldbus and machine-level Ethernet distribution.
  • PLC-to-HMI communications.
  • Compact control panel integration.

Technical Specifications

Manufacturer Omron
Part Number / Model W4S1-03B
Product Series W4S1 Industrial Switching Hubs
Number of Ports 3
Ethernet Standards IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX
Power Supply Voltage 24 VDC (plus/minus 5%)
Current Consumption 0.22 A
Power Consumption 5.28 W max.
Inrush Current lp = 1.42 A
Buffer Capacity 80 KB
MAC Address Capacity 2,000
Dimensions (H x W x D) 9.0 cm x 7.8 cm x 2.5 cm (approximate)
Shipping Weight 2.0 kg
Included Accessories Power supply connector

Connections and Interfaces

Interface Type Function / Description
RJ45 Ports (1-3) 10/100BASE-TX auto-sensing communication ports
Power Terminal Removable connector for 24 VDC input

Installation Guidelines

  • Mounting: Install within a clean, dry, and dust-free control cabinet. Ensure sufficient spacing around the module vents to facilitate heat dissipation.
  • Wiring: Always use shielded twisted-pair (STP) Ethernet cables (Category 5 or higher) to mitigate electromagnetic interference (EMI) in industrial zones.
  • Power Input: Use the supplied power supply connector to secure the 24 VDC source, maintaining the strict plus/minus 5% voltage tolerance window.

FAQ

What power supply voltage is required for the Omron W4S1-03B?

The W4S1-03B requires a stable nominal voltage of 24 VDC within a tolerance of plus/minus 5%.

Does the W4S1-03B switch package include a power connector?

Yes, a dedicated power supply terminal connector is included as standard with the W4S1-03B module.

What Ethernet speeds and standards are supported by this industrial hub?

The device features 3 ports that support IEEE 802.3 10BASE-T and IEEE 802.3u 100BASE-TX standards for fast Ethernet performance.

What is the buffer size and MAC address capacity of this module?

The W4S1-03B has an internal buffer memory capacity of 80 KB and a MAC address lookup table that holds up to 2,000 address entries.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.