Schneider Electric

Schneider Altistart 46 ATS46C48N Soft Starter

SKU ATS46C48N

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Schneider Electric

  • Product No.: ATS46C48N

  • Country of origin:France

  • Product Type: Soft starters

  • Payment: T/T, Western Union

  • Weight: 20000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The ATS46C48N is an Altistart 46 soft starter designed for the controlled starting and stopping of high-power three-phase asynchronous motors. This unit is rated for a continuous operational current of 480 A. It utilizes advanced solid-state technology to provide a smooth voltage ramp, which effectively reduces mechanical shock to connected machinery and limits inrush current during the starting phase. The ATS46C48N is engineered to maintain equipment longevity and improve overall power system stability in demanding industrial environments.

Features

  • Rated operational current: 480 A
  • Provides soft-start and soft-stop functionality
  • Reduces mechanical stress on gears, belts, and couplings
  • Minimizes voltage drops during motor startup
  • Durable design for high-demand industrial applications

Applications

  • Large-scale pumping systems
  • High-inertia fan and ventilation drives
  • Industrial compressors
  • Heavy-duty conveyor systems
  • Large machinery drive trains

Technical Specifications

Specification Details
Manufacturer Schneider Electric
Range Altistart
Subrange 46
Product Type Soft starters
Rated Current 480 A
Weight 20.00 kg
Commodity Code 85044095
Product Status Obsolete

Installation Guidelines

  • Mounting: Ensure the unit is installed in a vertical orientation on a rigid, heat-resistant surface to facilitate proper airflow.
  • Ventilation: Maintain adequate clearance around the cooling components to prevent overheating during continuous or frequent cycling.
  • Wiring: Use power cables sized appropriately for the 480 A load. Ensure terminal connections are tight to prevent localized heating.
  • Grounding: A secure connection to the facility's protective earth (PE) system is mandatory for operational safety and electromagnetic compatibility.
  • Environment: Protect the internal components from dust, moisture, and corrosive substances to ensure reliable operation in harsh industrial sites.

FAQ

What is the rated operational current of the ATS46C48N?

This soft starter is rated for a continuous operational current of 480 A.

What is the primary benefit of using this soft starter?

It provides a controlled start and stop for asynchronous motors, which reduces mechanical stress on equipment and limits electrical inrush current.

What is the current lifecycle status of the Altistart 46 series?

The Altistart 46 series is currently classified as an obsolete product.

How should this unit be mounted for proper operation?

The unit must be mounted vertically on a rigid, heat-resistant surface with sufficient clearance to allow for proper air circulation.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
France
Power source
AC-powered

Technical knowledge

Selecting and Troubleshooting DIN Valve Connectors

A practical guide to selecting, wiring and diagnosing DIN-style valve connectors, including form identification, coil voltage, suppression, polarity, sealing, release-time effects and commissioning...

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.

Grounded or Floating 24 VDC? A Control-Panel Decision Guide

Grounding one side of a 24 VDC supply can improve fault detection and voltage reference, while floating circuits support isolation. This guide explains bonding, noise, first-fault behavior, and...