Schneider Electric

Schneider Electric ATS22D32Q Altistart 22 Soft Starter

SKU ATS22D32Q

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Schneider Electric

  • Product No.: ATS22D32Q

  • Country of origin:France

  • Product Type: Soft starters

  • Payment: T/T, Western Union

  • Weight: 5650g

  • Dimensions: 33,5cm x 27cm x 22cm

  • Shipping port: Xiamen

  • Warranty: 12 months

The ATS22D32Q is a Soft Starter from the Altistart 22 range, engineered for the control of three-phase asynchronous motors. Designed to provide smooth starting and stopping sequences, this unit manages current and torque to prevent mechanical stress during startup. With a rated current of 32 A and a supply voltage range of 230V to 440V, it is capable of supporting motor applications ranging from 7.5 kW to 22 kW.

Features

  • Rated Current: 32 A
  • Supply Voltage: 230...440V
  • Motor Power Range: 7.5 to 22 kW
  • Optimized startup current to reduce mechanical and electrical stress
  • Compact dimensions for space-efficient panel integration

Applications

  • Pumps and fan systems
  • Centrifugal machines
  • Conveyor systems
  • Compressors
  • General industrial motor control

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Range Altistart 22
Product Type Soft starters
Rated Current 32 A
Supply Voltage 230...440V
Motor Power 7.5...22 kW
Dimensions 33.5 x 27 x 22 cm
Weight 5.65 kg
Commodity Code 84798997
Product Phase Active
Country of Origin France

Installation Guidelines

  • Mounting: Ensure vertical mounting within the control panel. Maintain adequate clearance above and below the unit to facilitate necessary airflow for cooling.
  • Wiring: Connect the three-phase supply and motor leads to the appropriate power terminals. Ensure all wiring is rated for the 32 A operational current.
  • Grounding: Establish a robust connection to a protective earth to ensure safe operation and mitigate electrical noise.
  • Environment: Install in a clean, dry location protected from extreme temperature fluctuations and excessive dust or moisture.
  • Commissioning: Verify motor settings and supply parameters before initiating the first start sequence.

FAQ

What is the rated current for the ATS22D32Q?

This soft starter has a rated current of 32 A.

What motor power range does this device support?

It is designed for asynchronous motors with power ratings from 7.5 kW to 22 kW.

What supply voltage does this unit accept?

The operating voltage range is 230 V to 440 V.

Is the Altistart 22 series currently active?

Yes, this model is in the Active phase of its lifecycle.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
France
Power source
AC-powered

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.