Schneider Electric

Schneider Electric ATS46C17N Altistart 46 Soft Starter

SKU ATS46C17N

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Schneider Electric

  • Product No.: ATS46C17N

  • Country of origin:France

  • Product Type: Soft starters

  • Payment: T/T, Western Union

  • Weight: 12350g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The ATS46C17N is a 176A industrial soft starter designed to optimize motor performance and reduce mechanical stress during startup. This electronic motor starter provides controlled voltage ramps to minimize inrush current surges and protect connected mechanical systems. Built for demanding industrial environments, the ATS46C17N supports smooth acceleration to extend equipment lifespan and improve operational reliability. Facility managers and electrical engineers rely on this controller for dependable motor management in legacy automation architectures.

Features

  • 176A current rating for robust industrial motor control
  • Controlled voltage ramp for reduced inrush current and mechanical stress
  • Smooth motor acceleration to extend equipment service life
  • Designed for demanding automation and production environments
  • Manufactured for reliable integration into established electrical systems

Applications

  • Centrifugal pumps and fluid handling systems
  • Industrial fans, blowers, and air handling units
  • Belt conveyors and material handling machinery
  • Compressors and heavy-duty industrial drives

Technical Specifications

Specification Category Parameter Value
General Brand Schneider Electric
General Manufacturer Schneider Electric
General Range Altistart
General Subrange 46
General Type of product Soft starters
General PLM Product phase Obsolete
Logistics Weight 12.35kg
Logistics Commodity Code 85044095
Logistics Export Control Regulations (ECCN) N

Installation Guidelines

  • Ensure proper vertical panel mounting with adequate clearance above and below the unit for natural convection cooling.
  • Route power cables and control wiring separately to prevent electromagnetic interference.
  • Verify correct torque on all power terminal connections prior to system energization.

FAQ

What is the current rating of the ATS46C17N soft starter?

The soft starter has a current rating of 176A.

What is the primary function of this unit?

It provides controlled voltage ramps to reduce inrush current and minimize mechanical stress during motor startup.

What product range does this soft starter belong to?

It belongs to the Altistart 46 range by Schneider Electric.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Beige
Country of origin
France
Power source
AC-powered

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.