Schneider Electric

Schneider Electric TeSys D GV2AF01 Connection Blocks

SKU GV2AF01

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Schneider Electric

  • Product No.: GV2AF01

  • Country of origin:France

  • Product Type: Connection Blocks

  • Payment: T/T, Western Union

  • Weight: 10g

  • Dimensions: 5,5cm x 4,1cm x 3,7cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The GV2AF01 is a TeSys D connection block engineered by Schneider Electric to provide secure electrical and mechanical linking between GV2ME circuit breakers and LC1K contactors. This specialized wiring accessory ensures reliable power distribution and seamless modular assembly within motor starter combinations. Designed with a compact form factor, it facilitates clean control panel layouts and efficient installation. Typical industrial applications include direct-on-line motor starters, machine tool control panels, and automated production line power circuits. It is fully compatible with standard Schneider Electric TeSys motor control components.

Features

  • TeSys D connection block designed for GV2ME and LC1K motor starter assemblies
  • Provides secure electrical and mechanical linking between circuit breakers and contactors
  • Compact and robust design optimized for control cabinet integration
  • Engineered for reliable operational lifespan in frequent switching applications

Applications

  • Direct-on-line (DOL) motor starter assemblies
  • Industrial machinery control panels and automated production lines
  • Power distribution and motor protection circuits

Technical Specifications

Technical Parameter Specification
Brand Schneider Electric
Manufacturer Schneider Electric
Range TeSys D
Type of product Connection blocks
Compatible Range GV2ME / LC1K
Product phase Active
Dimensions 5.50 x 4.10 x 3.70 cm
Weight 0.01 kg
Commodity Code 85366990
Export Control Regulations (ECCN) N

Installation Guidelines

  • Align the connection block securely between the compatible GV2ME circuit breaker and LC1K contactor terminals according to assembly guidelines.
  • Fasten all terminal connections firmly to ensure proper electrical contact and mechanical stability.
  • Verify correct alignment and physical clearance before mounting the assembled starter unit onto the standard DIN rail.
  • Check control wiring and power paths prior to energizing the motor starter circuit.

FAQ

What is the primary function of the GV2AF01 connection block?

It provides secure electrical and mechanical linking between GV2ME circuit breakers and LC1K contactors in motor starter assemblies.

Which product ranges are compatible with this connection accessory?

It is designed specifically for integration with Schneider Electric TeSys components, including the GV2ME and LC1K series.

What are the physical dimensions and weight of the unit?

The dimensions are 5.50 cm by 4.10 cm by 3.70 cm, with a total weight of 0.01 kg.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
France

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.