Schneider Electric

Schneider Electric TSXPBSCA400 Modicon Quantum Profibus DP Connection Cable

SKU TSXPBSCA400

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Schneider Electric

  • Product No.: TSXPBSCA400

  • Country of origin:France

  • Product Type: Profibus DP Connection Cable

  • Payment: T/T, Western Union

  • Weight: 23200g

  • Dimensions: 50 x 50 x 41.5 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The TSXPBSCA400 (TSX-PBS-CA400) is a high-performance Profibus DP connection cable engineered for the Modicon Quantum automation platform. Spanning a total length of 400 meters, this specialized communication medium is designed to facilitate seamless data exchange between PLC processors and remote I/O stations in demanding industrial environments such as oil refineries, power generation plants, and large-scale mining operations. Given its Phase-Out status, securing this original Schneider Electric component is critical for maintaining legacy infrastructure integrity, preventing costly downtime, and ensuring the deterministic performance required for mission-critical control loops.

Technical Configuration

As a dedicated Profibus DP (Decentralized Periphery) physical layer component, this cable features optimized impedance and shielding characteristics to mitigate electromagnetic interference (EMI) over long-distance runs. The 400-meter bulk reel allows for custom length termination or extensive trunk line deployment without the need for additional repeaters in many standard RS-485 network topologies. It is fully compliant with the Modicon Quantum architecture, supporting high-speed cyclic data exchange and diagnostics across the Profibus fieldbus network.

Technical Specifications

Attribute Specification
Model TSXPBSCA400
Brand Schneider Electric
Range Modicon Quantum
Product Type Profibus DP Connection Cable
Cable Length 400 meters
Weight 23.20 kg
Dimensions 50 x 50 x 41.5 cm
Commodity Code 85444290
Operating Temp -20 to +70 deg C
Communication Protocol Profibus DP

Technical FAQs

Is the TSXPBSCA400 compatible with other Modicon series?

While specifically categorized under the Modicon Quantum range, this cable follows standard Profibus DP physical layer specifications and can be utilized with Modicon M580 or M340 systems provided the appropriate Profibus communication modules and connectors are employed.

How does the Phase-Out status affect future maintenance?

As this product is in the Phase-Out phase, Schneider Electric may limit new production. It is highly recommended to maintain onsite spares to ensure immediate recovery during cable damage scenarios, as lead times for legacy accessories typically increase over time.

What are the grounding requirements for a 400-meter run?

To prevent ground loops while maintaining EMI protection, the cable shield should be integrated via 360-degree contact at the connector level. In extended runs, ensure that the potential equalization between different plant areas is within the specified limits of the Profibus standard.


Engineering & Installation Guide

  • Minimum Bend Radius: During installation, maintain a minimum bend radius of at least 15 times the outer diameter of the cable. Excessive kinking can alter the internal geometry of the twisted pair, leading to signal reflection and intermittent "Bus Heavy" errors in the PLC diagnostics.

  • Separation from Power Lines: To maintain signal integrity, route this cable in separate conduits from high-voltage motor leads or VFD outputs. A minimum clearance of 20 cm is recommended in parallel runs to prevent inductive coupling.

  • Environmental Protection: Although designed for industrial use, if the cable is routed through areas with high chemical exposure or standing water, it must be protected by liquid-tight flexible conduits. Ensure all Profibus connectors are tightened to the specified torque to maintain IP-rated seals at the module interface.

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Purple
Country of origin
France

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.