Description

This Siemens 6AV7240-3DC04-0PA0 is a SIMATIC IPC 477D series Panel PC designed for industrial HMI and control applications. It features a 19-inch touch display integrated with a processing unit powered by an Intel Core i3-3217UE CPU. The system is equipped with 4 GB of RAM and a 240 GB MLC SSD for reliable, fast-access storage. Connectivity is provided through dual Gigabit Ethernet ports, multiple USB interfaces, and an RS-232 serial port. This unit is configured to operate on a 24 V DC industrial power supply and comes with Windows Embedded Standard 7 (32-bit).

Features

  • 19-inch resistive touch display
  • Intel Core i3-3217UE processor
  • 4 GB installed system memory (RAM)
  • 240 GB MLC Solid-State Drive (SSD) for storage
  • Dual Gigabit Ethernet ports (IE/PN) for network connectivity
  • Five USB ports (4 rear, 1 front)
  • One RS-232 serial interface
  • Designed for 24 V DC industrial power supply

Applications

  • Human-Machine Interface (HMI) for process visualization
  • Machine-level data acquisition and logging
  • Supervisory control nodes in manufacturing cells
  • Industrial gateways and communication servers

Technical Specifications

Specification Value
Brand Siemens
Model 6AV7240-3DC04-0PA0
Series SIMATIC IPC 477D
Product Type Panel PC
Lifecycle Status Phase-Out
Display 19-inch Touch Display
Processor Intel Core i3-3217UE
Memory (RAM) 4 GB
Storage 240 GB Standard SSD (MLC)
Ethernet Ports 2 x Gigabit Ethernet (10/100/1000 Mbps), IE/PN compatible
USB Ports 5 total (4 x rear, 1 x front)
Serial Port 1 x RS-232
Expansion Slots Without PCIe
Operating System Windows Embedded Standard 7, 32-bit
Included Software Without SIMATIC Software
Power Supply 24 V DC
Shipping Weight 6.40 kg
Package Dimensions (Calculated) 61.0 x 41.0 x 18.0 cm
Commodity Code 85371098
ECCN N
Country of Origin Germany (Estimated)
Manufacturer Siemens

Installation Guidelines

CRITICAL WARNING: RISK OF ELECTRIC SHOCK

Disconnect all power sources to the enclosure and follow lock-out/tag-out (LOTO) procedures before installation or servicing. Installation must be performed by qualified personnel familiar with industrial control panel standards and practices.

  1. 1 Verify the panel cutout dimensions match the IPC 477D installation requirements. Ensure the mounting surface is clean, flat, and provides adequate structural support.
  2. 2 Insert the Panel PC into the prepared cutout from the front of the enclosure. Secure the unit from the rear using the provided mounting clamps, tightening them evenly to the manufacturer's specified torque to ensure a proper seal.
  3. 3 Connect a low-impedance protective earth (PE) conductor to the designated grounding terminal on the Panel PC chassis. This is essential for safety and EMI protection.
  4. 4 Connect the 24 V DC power supply to the unit's power connector, ensuring correct polarity. Use appropriately sized wiring for the load and route it away from high-voltage or high-frequency cables.
  5. 5 Connect Ethernet, USB, and any serial communication cables as required by the application. Ensure all connectors are fully seated and secured.
  6. 6 After verifying all connections are correct and secure, remove LOTO devices and re-energize the control panel. Power on the Panel PC and verify correct boot-up and operation.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...