Description
This is a Siemens 6AV7240-6DD07-0HA0 SIMATIC IPC 477D, a robust panel PC designed for industrial automation and control applications. It features a 19-inch touch display and is powered by an Intel Core i7-3517UE processor. The unit is configured with 8 GB of RAM and an 80 GB MLC Solid State Drive (SSD) for reliable performance. It operates on a 24 V DC industrial power supply and comes pre-installed with Windows 7 Ultimate (64-bit). Connectivity is provided through dual Gigabit Ethernet ports, multiple USB interfaces, and an RS-232 serial port.
Features
- 19-inch resistive touch display for operator interaction.
- Intel Core i7-3517UE central processing unit.
- 8 GB of integrated system memory.
- 80 GB Standard (MLC) Solid State Drive for storage.
- Dual Gigabit Ethernet ports supporting IE/PN protocols.
- Five USB ports (4 rear, 1 front) for peripheral connectivity.
- Pre-installed with Windows 7 Ultimate (64-bit) operating system.
- Powered by a 24 V DC industrial power source.
Applications
- Human-Machine Interface (HMI) for process visualization.
- Supervisory Control and Data Acquisition (SCADA) nodes.
- Machine control and data logging in manufacturing environments.
- Industrial data processing and plant floor computing.
Technical Specifications
| Specification |
Value |
| Manufacturer |
Siemens |
| Product Series |
SIMATIC IPC 477D |
| Display |
19" Touch Display |
| Processor |
Intel Core i7-3517UE |
| Memory (RAM) |
8 GB |
| Storage |
80 GB Standard (MLC) SSD |
| Operating System |
Windows 7 Ultimate, 64-bit |
| Power Supply |
24 V DC Industrial Power Supply |
| Ethernet Ports |
2x Gigabit Ethernet (10/100/1000 Mbps), IE/PN compatible |
| USB Ports |
4x Rear, 1x Front |
| Serial Port |
1x RS-232 |
| Expansion Slots |
Without PCIe |
| Product Lifecycle Status |
Phase-Out |
| Shipping Weight |
6.40 kg |
| Shipping Dimensions |
61.00 x 41.00 x 18.00 cm |
| Country of Origin |
Germany (Estimate) |
Installation Guidelines
CRITICAL WARNING: Disconnect all power sources before installation or maintenance. Failure to de-energize the system can result in severe electrical shock, equipment damage, or personal injury. Always follow local Lockout/Tagout (LOTO) procedures.
-
1
Ensure the mounting surface or panel cutout is clean, flat, and meets the dimensional requirements for the IPC 477D chassis. Verify adequate clearance for ventilation and cable routing.
-
2
Secure the Panel PC into the cutout using the provided mounting clamps. Apply torque evenly to all clamps to ensure a proper seal and prevent chassis distortion.
-
3
Connect the 24 V DC power supply to the designated power input terminal. Ensure the power source is stable, properly rated, and correctly polarized. Connect the functional earth (FE) terminal to the cabinet's equipotential bonding system.
-
4
Connect Ethernet, USB, and serial communication cables as required by the application. Use shielded cables for all data lines and ensure shields are properly terminated to the grounded chassis to minimize EMI/RFI interference.
-
5
After all connections are verified, restore power to the unit. Proceed with software configuration and system commissioning according to project requirements.