Siemens

Siemens 6AV7462-0AC30-0BK0 SIMATIC Panel PC 677

SKU 6AV7462-0AC30-0BK0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7462-0AC30-0BK0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 35.00 x 25.00 x 25.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This is a Siemens 6AV7462-0AC30-0BK0, a SIMATIC Panel PC 677 designed for industrial HMI and control applications. This unit is configured as a Fat Client and features a 15-inch display with integrated function keys. It is powered by a Pentium M 2.0 GHz processor and is equipped with 1 GB of RAM and an 80 GB hard drive. This model is supplied without a pre-installed operating system, providing flexibility for custom software deployment in legacy automation environments.

Features

  • 15-inch front panel with 2x6 integrated function keys for operator input.
  • Pentium M processor operating at a clock speed of 2.0 GHz.
  • Includes 1 GB of installed system RAM.
  • Equipped with an 80 GB hard drive for local data and application storage.
  • Shipped without an operating system, enabling custom software installation.
  • Designated as an obsolete product, ideal for spare parts and maintenance of existing systems.

Applications

  • Human-Machine Interface (HMI) for machine control and monitoring.
  • Supervisory Control and Data Acquisition (SCADA) nodes.
  • Process visualization in manufacturing and production lines.
  • Data logging and reporting at the machine level.
  • Replacement unit for legacy SIMATIC PC-based control systems.

Technical Specifications

Specification Value
Manufacturer Siemens
Part Number 6AV7462-0AC30-0BK0
Product Line SIMATIC Panel PC
Series PC 677
Product Type Panel PC
Processor Pentium M, 2.0 GHz
Memory (RAM) 1 GB
Storage 80 GB Hard Drive (HD)
Display Size 15 inch
Integrated Keys 2 x 6 Function Keys
Operating System Not Included
Product Lifecycle Status Obsolete
Shipping Weight 12.00 kg
Package Dimensions (Calculated) 35.00 x 25.00 x 25.00 cm
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimate)

Installation Guidelines

CRITICAL WARNING: Installation must be performed by qualified personnel only. Failure to adhere to safety procedures can result in equipment damage, severe injury, or death. Always de-energize and lock out/tag out (LOTO) all power sources before installation or maintenance. Use appropriate personal protective equipment (PPE) and electrostatic discharge (ESD) protection.
  1. 1 Prepare the Enclosure: Ensure the control cabinet is de-energized and verified to be at a zero-energy state. Confirm that the panel cutout dimensions match the PC 677's mounting requirements. Clean the mounting surface to ensure a proper seal.
  2. 2 Mount the Unit: Carefully insert the Panel PC into the cutout from the front of the enclosure. Ensure the front bezel gasket is properly seated against the panel surface to maintain the specified ingress protection rating.
  3. 3 Secure Mounting Clamps: From the rear of the unit, install and tighten the provided mounting clamps evenly around the perimeter. Apply torque sequentially and uniformly to avoid deforming the bezel and to ensure a consistent seal.
  4. 4 Connect Power and Ground: Connect the main power supply to the designated input terminals. Crucially, connect the functional earth (FE) or protective earth (PE) terminal to the cabinet's ground bus using a low-impedance conductor to ensure safety and noise immunity.
  5. 5 Connect Peripherals: Connect all required interface cables, such as Ethernet, USB, and serial communications. Ensure proper cable strain relief and routing to prevent accidental disconnection and interference.
  6. 6 Final Checks and Power-Up: After all connections are secure, remove LOTO devices and re-energize the cabinet. Power on the Panel PC and proceed with operating system and application software installation as required.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap