The Siemens
6AV7611-0AA20-0BE0 is a
SIMATIC Panel PC 670, an industrial panel PC designed for visualization and control tasks. This unit features a
10-inch TFT display, a standard configuration including a
20 GB hard drive,
128 MB of RAM, and is powered by a
Celeron 300 MHz CPU. It operates on a
115-230 V AC power supply and comes with a U.S. mains cable. The system is pre-installed with
Windows 98 in German, making it suitable for specific legacy industrial applications requiring this operating environment.
Features
- 10-inch TFT Display
- 20 GB Hard Drive (HD)
- 128 MB RAM
- Celeron 300 MHz CPU
- 115-230 V AC Power Input (U.S. Mains Cable included)
- Pre-installed Windows 98 (German version)
Applications
- Human-Machine Interface (HMI) for industrial processes
- Data visualization and operational control in manufacturing environments
- Integration into existing SIMATIC automation systems
- Machine control and monitoring requiring a compact PC solution
Technical Specifications
| Brand |
Siemens |
| Manufacturer |
Siemens |
| Range |
Simatic Panel PC |
| Subrange |
PC670 |
| Product Type |
PC panels |
| Display |
10-inch TFT |
| Storage |
20 GB HD |
| Memory |
128 MB RAM |
| Processor |
Celeron 300 MHz |
| Power Input |
115-230 V AC |
| Operating System |
Windows 98 German |
| Product Phase |
Obsolete |
| Shipping Weight |
4.00 kg |
| Commodity Code |
85371091 |
| Export Control Regulations (ECCN) |
N |
Installation Guidelines
-
Safety First: Ensure all power to the installation area is de-energized before beginning any work.
-
Mounting: Securely mount the Panel PC into a suitable panel cutout or enclosure, ensuring adequate ventilation clearances around the unit.
-
Power Connection: Connect the provided U.S. mains cable to a compatible 115-230 V AC power source. Verify correct voltage and grounding.
-
Grounding: Establish a proper protective earth (PE) connection to the Panel PC chassis to ensure electrical safety and minimize electromagnetic interference.
-
Peripheral Connections: Connect any necessary industrial peripherals (e.g., keyboard, mouse, network cables) to the appropriate ports.
-
Environmental Considerations: Ensure the operating environment meets the specified temperature, humidity, and vibration limits for industrial PC equipment. Avoid direct exposure to excessive dust, moisture, or corrosive agents.
-
Power Up: After all connections are verified, re-energize the power supply to the Panel PC.