Description

The Siemens 6AV7611-0AA22-0AE0 is a SIMATIC Panel PC 670, an industrial-grade human-machine interface (HMI) designed for control and visualization tasks in manufacturing environments. This unit features a 10-inch TFT display and is powered by an Intel Pentium III 500 MHz processor. It is configured with 128 MB of RAM, a 20 GB hard drive, and operates on a 24 VDC power supply. This specific model comes pre-installed with a German-language version of the Windows 98 operating system.

Features

  • 10-inch color TFT display for process visualization.
  • Powered by an Intel Pentium III 500 MHz CPU.
  • Equipped with 128 MB of system RAM.
  • Includes a 20 GB hard drive for data and application storage.
  • Operates on a standard 24 VDC industrial power source.
  • Pre-loaded with Windows 98 operating system (German language).

Applications

  • Human-Machine Interface (HMI) for machine control.
  • SCADA client for plant-level monitoring.
  • Process data logging and visualization.
  • Control panel for automated assembly lines.
  • Legacy system integration and monitoring.

Technical Specifications

Specification Value
Brand Siemens
Model Number 6AV7611-0AA22-0AE0
Product Series SIMATIC Panel PC 670
Product Type Panel PC
Display 10 inch TFT
Processor (CPU) Intel Pentium III, 500 MHz
Memory (RAM) 128 MB
Storage 20 GB Hard Drive (HD)
Power Supply Input 24 VDC
Operating System Windows 98 (German)
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Harmonized Tariff Code 85371091
ECCN N
Package Dimensions (Calculated) 40 x 30 x 15 cm

Installation Guidelines

CRITICAL WARNING: RISK OF ELECTRIC SHOCK

Installation must be performed by qualified personnel only. Disconnect all power sources and implement Lockout/Tagout (LOTO) procedures before accessing or installing this equipment. Failure to de-energize the system can result in severe injury or death.

  1. 1 Panel Cutout and Mounting: Prepare the control cabinet panel cutout according to the device's mechanical drawings. Ensure the mounting surface is clean, flat, and rigid. Insert the Panel PC into the cutout and secure it evenly using all provided mounting clamps to maintain the specified ingress protection rating. Do not overtighten the clamps.
  2. 2 Protective Earth (PE) Connection: Connect the chassis to the control cabinet's protective earth busbar using a low-impedance, short-gauge wire. A reliable earth connection is critical for operator safety and electromagnetic compatibility (EMC).
  3. 3 Power Supply Wiring: Connect the 24 VDC power supply to the designated terminals. Verify the polarity (+/-) is correct before energizing. Use appropriately sized conductors and ensure connections are torqued to specification. Route power cables separately from high-voltage or high-frequency signal cables.
  4. 4 Interface Connections: Connect all required communication and peripheral cables (e.g., Ethernet, USB, serial). Ensure all connectors are fully seated and secured. Use shielded cables for communication lines and ground the shields at one end, typically at the cabinet ground bar, to minimize noise interference.
  5. 5 System Power-Up: After verifying all connections and clearing the work area, remove LOTO devices and apply power to the cabinet. Observe the Panel PC's boot sequence to ensure the operating system loads correctly. Proceed with software configuration and commissioning.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.

Grounded or Floating 24 VDC? A Control-Panel Decision Guide

Grounding one side of a 24 VDC supply can improve fault detection and voltage reference, while floating circuits support isolation. This guide explains bonding, noise, first-fault behavior, and...

Seal-In Logic or OTL/OTU? Choosing PLC Memory Safely

Seal-in circuits and OTL/OTU instructions can hold the same command, but they fail differently. This guide compares scan behavior, restart risk, troubleshooting, permissives, and safer PLC design...