Description
This is a Siemens 6AV7611-0AA32-0BH0 SIMATIC Panel PC 670, an industrial human-machine interface (HMI) designed for machine-level control and visualization. This standard configuration features a 10-inch TFT display, a Pentium III 500 MHz CPU, 256 MB of RAM, and a 20 GB hard drive. The unit is pre-installed with the Windows NT 4.0 operating system in German and is powered by a 115-230V AC supply via the included U.S. mains cable. Please note that this product is considered obsolete by the manufacturer, making it suitable for legacy system maintenance and spare parts inventory.
Features
-
Integrated 10-inch TFT color display for process visualization.
-
Powered by an Intel Pentium III 500 MHz processor.
-
Equipped with 256 MB of system RAM.
-
Includes a 20 GB internal hard drive for storage.
-
Pre-loaded with Windows NT 4.0 (German language version).
-
Flexible power input range of 115-230V AC.
Applications
-
Replacement HMI for existing SIMATIC-based automation systems.
-
Machine-level operator control and monitoring panels.
-
Data acquisition and logging nodes in manufacturing environments.
-
Process visualization for small to medium-sized applications.
Technical Specifications
| Specification |
Value |
| Manufacturer |
Siemens |
| Product Series |
SIMATIC Panel PC 670 |
| Part Number |
6AV7611-0AA32-0BH0 |
| Product Type |
Panel PC |
| Display |
10-inch TFT |
| Processor (CPU) |
Pentium III, 500 MHz |
| Memory (RAM) |
256 MB |
| Storage |
20 GB Hard Drive (HD) |
| Operating System |
Windows NT 4.0 (German) |
| Power Supply |
115-230 V AC (U.S. Mains Cable included) |
| Product Lifecycle Status |
Obsolete |
| Shipping Weight |
4.00 kg |
| Commodity Code |
85371091 |
| ECCN |
N |
| Country of Origin |
Germany (Estimate) |
| Package Dimensions (Calculated) |
35 x 28 x 15 cm |
Installation Guidelines
CRITICAL WARNING: RISK OF ELECTRIC SHOCK
Disconnect all power sources before installation or servicing. Work must be performed by qualified personnel only. Failure to comply with Lockout/Tagout (LOTO) procedures can result in severe injury or death.
-
1
Prepare Mounting Location
Ensure the control panel cutout matches the PC's dimensions. Verify adequate clearance for ventilation and cable routing behind the unit. The mounting surface must be clean, flat, and able to support the device weight.
-
2
Install the Panel PC
Insert the Panel PC into the prepared cutout from the front. Secure it from the rear using the provided mounting clamps. Tighten the clamp screws evenly in a cross pattern to ensure a uniform seal against the panel gasket. Do not overtighten.
-
3
Connect Protective Earth (PE)
Connect a low-impedance protective earth conductor to the designated PE terminal on the Panel PC chassis. This is a critical safety connection to protect against electrical faults.
-
4
Connect Power and Peripherals
With the main power source de-energized, connect the AC mains cable to the unit's power inlet. Connect any required communication cables (e.g., Ethernet, serial) and I/O devices. Ensure all connectors are fully seated and secured.
-
5
Power-Up and Verification
Clear the work area and restore power to the circuit. Power on the Panel PC and verify that the operating system boots correctly. Check for proper display function and establish communication with other network devices as required.