Description
This Siemens 6AV7611-0AB12-0CE0 is a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) applications. It features a 10-inch TFT display, a Pentium III 500 MHz CPU, and is configured with 64 MB of RAM and a 20 GB hard drive. This unit includes a CD-ROM drive and is pre-installed with a German version of Windows 98. It operates on a 115-230V AC power supply and is supplied with a European mains cable.
Features
- 10-inch TFT color display for clear visualization
- Intel Pentium III 500 MHz processor
- 64 MB of system RAM
- 20 GB hard disk drive (HD) for data and application storage
- Integrated CD-ROM drive for software installation
- Pre-installed with Windows 98 (German language)
- Wide input voltage range of 115-230V AC
Applications
- Machine control and visualization
- Process monitoring and data acquisition
- Factory floor HMI stations
- Industrial control cabinet integration
Technical Specifications
| Specification |
Value |
| General |
| Brand |
Siemens |
| Series |
SIMATIC Panel PC 670 |
| Model Number |
6AV7611-0AB12-0CE0 |
| Product Type |
Panel PC |
| Processing & Memory |
| CPU |
Pentium III, 500 MHz |
| RAM |
64 MB |
| Storage |
| Hard Drive |
20 GB |
| Optical Drive |
CD-ROM |
| Display |
| Type |
TFT |
| Size |
10 inch |
| Software |
| Operating System |
Windows 98 (German) |
| Power Supply |
| Input Voltage |
115-230 V AC |
| Included Cable |
European Mains Cable |
| Product Lifecycle |
| PLM Status |
Obsolete |
| Logistics |
| Shipping Weight |
12.00 kg |
| Package Dimensions (Calculated) |
35.0 x 25.0 x 25.0 cm |
| Commodity Code |
85371091 |
| ECCN |
N |
| Country of Origin |
Germany (Estimated) |
| Manufacturer |
Siemens |
Installation Guidelines
CRITICAL WARNING: Hazardous voltages are present. Installation must be performed by qualified personnel only. Ensure all power sources are de-energized and locked out/tagged out (LOTO) before commencing any work. Failure to comply can result in severe injury or death.
-
1
Prepare Mounting Location: Ensure the panel cutout dimensions are correct and the mounting surface is clean, flat, and can support the weight of the unit (12.00 kg). Verify adequate clearance for ventilation and cable routing.
-
2
Mount the Panel PC: Insert the unit into the panel cutout from the front. Secure it from the rear using the provided mounting clamps, tightening them evenly to the manufacturer's specified torque to ensure a proper seal.
-
3
Connect Protective Earth (PE): Connect the chassis ground terminal to the control cabinet's protective earth bus using a low-impedance conductor. This is critical for safety and noise immunity.
-
4
Connect Power Supply: Connect the provided European mains cable to the unit's power input and a suitable 115-230V AC source. Ensure the power source is stable and properly fused.
-
5
Connect Peripherals: Connect any required peripherals such as keyboards, mice, and network cables to their respective ports. Power on the unit only after all connections are secure and the work area is clear.