Description
The Siemens 6AV7611-0AE22-0AJ0 is a SIMATIC Panel PC 670, an industrial PC panel designed for human-machine interface (HMI) and control applications. This unit features a 10" TFT display, a standard configuration including a 40 GB hard drive, and 128 MB of RAM. It is powered by a Pentium III 500 MHz CPU and operates on a 24 V DC power supply. The system comes pre-installed with Windows NT 4.0 English, making it suitable for integration into existing industrial automation environments. The 6AV7611-0AE22-0AJ0 is classified as an obsolete product phase.
Features
- 10" TFT Display
- 40 GB Hard Drive
- 128 MB RAM
- Pentium III 500 MHz CPU
- 24 V DC Power Input
- Pre-installed Windows NT 4.0 English Operating System
Applications
- Industrial Human-Machine Interface (HMI)
- Machine control and visualization
- Process monitoring and data acquisition
- Factory automation systems
- Data logging and supervisory control
Technical Specifications
| Parameter |
Value |
| Brand |
Siemens |
| Manufacturer |
Siemens |
| Range |
SIMATIC Panel PC |
| Subrange |
PC670 |
| Product Type |
PC panels |
| Display |
10" TFT |
| Hard Drive |
40 GB |
| RAM |
128 MB |
| CPU |
Pentium III 500 MHz |
| Power Supply |
24 V DC |
| Operating System |
Windows NT 4.0 English |
| Product Phase |
Obsolete |
| Logistics Weight |
4.00 kg |
| Commodity Code |
85371091 |
| Export Control Regulations (ECCN) |
N |
Installation Guidelines
-
De-energize System: Ensure all power to the control cabinet or mounting location is disconnected before commencing installation.
-
Mounting: Securely mount the Panel PC into the designated panel cutout, ensuring proper sealing to maintain environmental protection.
-
Power Connection: Connect the 24 V DC power supply to the appropriate terminals, observing correct polarity. Verify the power source meets the specified voltage and current requirements.
-
Grounding: Establish a robust protective earth (PE) connection to the Panel PC chassis to ensure safety and minimize electromagnetic interference.
-
Peripheral Connections: Connect any necessary peripherals such as keyboards, mice, or network cables to the available ports.
-
Cable Management: Route all cables neatly and securely, ensuring they are not subjected to strain, sharp edges, or potential interference from power lines.
-
Power Up: Once all connections are verified, re-energize the system and observe for proper boot-up and operation.