Siemens

Siemens 6AV7611-0AF32-0AF0 SIMATIC Panel PC 670

SKU 6AV7611-0AF32-0AF0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7611-0AF32-0AF0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 40 x 30 x 15 cm (Estimate)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7611-0AF32-0AF0 is a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This unit features a 10-inch TFT display and is powered by a Pentium III 500 MHz processor. It is configured with 256 MB of RAM, a 40 GB hard drive, and a CD-ROM drive. The system operates on a 24 V DC power supply and comes pre-installed with the Windows 98 operating system in English. Note that this model is considered an obsolete part, suitable for maintaining or repairing legacy automation systems.

Features

  • Integrated 10-inch TFT color display
  • Intel Pentium III processor operating at 500 MHz
  • 256 MB of system RAM
  • 40 GB hard drive for operating system and application storage
  • Includes a CD-ROM optical drive
  • Operates on a nominal 24 V DC industrial power source
  • Pre-loaded with Windows 98 (English version)

Applications

  • Machine-level operator control and monitoring
  • Process visualization and SCADA client stations
  • Data acquisition and logging in manufacturing environments
  • Replacement unit for existing SIMATIC PC 670 installations
  • Industrial control panels in factory automation

Technical Specifications

Category Value
Manufacturer Siemens
Product Series SIMATIC Panel PC 670
Model Number 6AV7611-0AF32-0AF0
Display 10 inch TFT
Processor (CPU) Pentium III, 500 MHz
Memory (RAM) 256 MB
Storage 40 GB Hard Drive (HD)
Optical Drive CD-ROM
Power Supply 24 V DC
Operating System Windows 98 (English)
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimate)
Package Dimensions (Calculated) 40 x 30 x 15 cm (Estimate)

Installation Guidelines

CRITICAL WARNING: Installation must be performed by qualified personnel only. Failure to de-energize all power sources before installation can result in severe injury, death, or equipment damage. Always follow local and national electrical codes and safety standards, including Lockout/Tagout (LOTO) procedures.
  1. 1 Prepare the Enclosure: Ensure the panel cutout dimensions match the PC 670's mounting requirements. The mounting surface must be clean, flat, and capable of supporting the unit's weight. Verify adequate clearance for ventilation and cable routing.
  2. 2 Mount the Unit: Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps. Tighten the clamp screws evenly in a crisscross pattern to ensure a uniform seal against the panel gasket. Do not overtighten.
  3. 3 Connect Power: Connect a stable, safety extra-low voltage (SELV/PELV) 24 V DC power source to the designated power terminals. Ensure correct polarity. Use appropriately sized wiring for the current draw and secure the connections firmly.
  4. 4 Establish Grounding: Connect the functional earth (FE) or protective earth (PE) terminal on the chassis to the enclosure's main ground point using a low-impedance conductor. Proper grounding is essential for noise immunity and safety.
  5. 5 Connect Peripherals: Connect any required communication cables (e.g., Ethernet, PROFIBUS) and I/O devices. Ensure all cable shields are properly terminated as required. Route cables away from high-voltage lines to minimize electrical noise interference.

FAQ

What is the required power supply voltage for this Panel PC?

The 6AV7611-0AF32-0AF0 requires a 24 V DC power supply.

Which operating system is installed on this unit?

This Panel PC comes with the Windows 98 operating system, English version, pre-installed.

What are the core hardware specifications of this model?

It is equipped with a Pentium III 500 MHz processor, 256 MB of RAM, a 40 GB hard drive, and a CD-ROM drive.

Is the 6AV7611-0AF32-0AF0 a current product?

No, this model is classified as an obsolete product, primarily used for spare parts and maintaining existing legacy systems.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.