Siemens

Siemens 6AV7612-0AA12-0AJ0 SIMATIC Panel PC 670

SKU 6AV7612-0AA12-0AJ0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7612-0AA12-0AJ0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 0.10 x 0.10 x 0.10 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7612-0AA12-0AJ0 is a SIMATIC Panel PC 670, designed as an industrial human-machine interface (HMI) with a 12-inch TFT touch display. This panel PC comes in a standard configuration featuring a 20 GB hard drive, 64 MB of RAM, and a Pentium III 500 MHz CPU. It operates on a 24 V DC power supply and is pre-installed with Windows NT 4.0 in English, making it suitable for various industrial control and visualization tasks.

Features

  • 12-inch TFT Touch Display
  • Pentium III 500 MHz CPU
  • 64 MB RAM
  • 20 GB Hard Drive
  • 24 V DC Power Input
  • Pre-installed Windows NT 4.0 (English)

Applications

The Siemens SIMATIC Panel PC 670 is typically deployed in industrial environments requiring robust HMI solutions. Common applications include:

  • Machine operation and control panels
  • Process visualization and monitoring systems
  • Data acquisition and supervisory control
  • Factory automation and manufacturing execution systems (MES)
  • Building automation and infrastructure management

Technical Specifications

Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Product Type PC panels
Display Type 12" TFT Touch Display
CPU Pentium III 500 MHz
RAM 64 MBYTE
Hard Drive 20 GB
Operating System Windows NT 4.0 (English)
Input Voltage 24 V DC
Product Phase Obsolete
Package Dimensions (Calculated) 0.10 x 0.10 x 0.10 cm
Shipping Weight 12.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

Proper installation ensures reliable operation and longevity of the SIMATIC Panel PC 670. Adhere to standard industrial practices:

  1. De-energize System: Ensure all power to the installation area is disconnected and locked out before beginning any work.
  2. Mounting: Mount the panel PC securely into a prepared panel cutout. Ensure adequate clearance for ventilation and cable routing.
  3. Power Connection: Connect the 24 V DC power supply, observing correct polarity. Use appropriately sized and shielded cables to minimize electrical noise.
  4. Grounding: Establish a robust protective earth (PE) connection to the panel PC chassis and the control cabinet's central grounding point.
  5. Cable Routing: Route signal and power cables separately to prevent interference. Secure all cables to prevent strain and accidental disconnection.
  6. Environmental Considerations: Ensure the operating environment is within the specified temperature and humidity ranges. Avoid areas with excessive vibration, dust, or corrosive gases.
  7. Initial Power-Up: After verifying all connections, re-energize the system and observe the panel PC's startup sequence.

FAQ

What is the primary function of the Siemens 6AV7612-0AA12-0AJ0?

It functions as an industrial Human-Machine Interface (HMI) for control and visualization tasks, featuring a 12-inch TFT touch display.

What operating system is pre-installed on this Panel PC?

The unit comes with Windows NT 4.0 (English) pre-installed.

What are the power requirements for this SIMATIC Panel PC?

The Panel PC requires a 24 V DC power supply for operation.

Can the hard drive or RAM be upgraded?

The standard configuration includes a 20 GB hard drive and 64 MB RAM. While physical upgrades might be possible, it is an obsolete product, and compatibility with modern components may be limited.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.