Siemens

Siemens 6AV7612-0AA12-0AJ0 SIMATIC Panel PC 670

SKU 6AV7612-0AA12-0AJ0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7612-0AA12-0AJ0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 0.10 x 0.10 x 0.10 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7612-0AA12-0AJ0 is a SIMATIC Panel PC 670, designed as an industrial human-machine interface (HMI) with a 12-inch TFT touch display. This panel PC comes in a standard configuration featuring a 20 GB hard drive, 64 MB of RAM, and a Pentium III 500 MHz CPU. It operates on a 24 V DC power supply and is pre-installed with Windows NT 4.0 in English, making it suitable for various industrial control and visualization tasks.

Features

  • 12-inch TFT Touch Display
  • Pentium III 500 MHz CPU
  • 64 MB RAM
  • 20 GB Hard Drive
  • 24 V DC Power Input
  • Pre-installed Windows NT 4.0 (English)

Applications

The Siemens SIMATIC Panel PC 670 is typically deployed in industrial environments requiring robust HMI solutions. Common applications include:

  • Machine operation and control panels
  • Process visualization and monitoring systems
  • Data acquisition and supervisory control
  • Factory automation and manufacturing execution systems (MES)
  • Building automation and infrastructure management

Technical Specifications

Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Product Type PC panels
Display Type 12" TFT Touch Display
CPU Pentium III 500 MHz
RAM 64 MBYTE
Hard Drive 20 GB
Operating System Windows NT 4.0 (English)
Input Voltage 24 V DC
Product Phase Obsolete
Package Dimensions (Calculated) 0.10 x 0.10 x 0.10 cm
Shipping Weight 12.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

Proper installation ensures reliable operation and longevity of the SIMATIC Panel PC 670. Adhere to standard industrial practices:

  1. De-energize System: Ensure all power to the installation area is disconnected and locked out before beginning any work.
  2. Mounting: Mount the panel PC securely into a prepared panel cutout. Ensure adequate clearance for ventilation and cable routing.
  3. Power Connection: Connect the 24 V DC power supply, observing correct polarity. Use appropriately sized and shielded cables to minimize electrical noise.
  4. Grounding: Establish a robust protective earth (PE) connection to the panel PC chassis and the control cabinet's central grounding point.
  5. Cable Routing: Route signal and power cables separately to prevent interference. Secure all cables to prevent strain and accidental disconnection.
  6. Environmental Considerations: Ensure the operating environment is within the specified temperature and humidity ranges. Avoid areas with excessive vibration, dust, or corrosive gases.
  7. Initial Power-Up: After verifying all connections, re-energize the system and observe the panel PC's startup sequence.

FAQ

What is the primary function of the Siemens 6AV7612-0AA12-0AJ0?

It functions as an industrial Human-Machine Interface (HMI) for control and visualization tasks, featuring a 12-inch TFT touch display.

What operating system is pre-installed on this Panel PC?

The unit comes with Windows NT 4.0 (English) pre-installed.

What are the power requirements for this SIMATIC Panel PC?

The Panel PC requires a 24 V DC power supply for operation.

Can the hard drive or RAM be upgraded?

The standard configuration includes a 20 GB hard drive and 64 MB RAM. While physical upgrades might be possible, it is an obsolete product, and compatibility with modern components may be limited.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...