Siemens

Siemens 6AV7612-0AA32-0BE0 SIMATIC Panel PC 670 Panel PC

SKU 6AV7612-0AA32-0BE0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7612-0AA32-0BE0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: Corrections Applied: none

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7612-0AA32-0BE0 is a SIMATIC Panel PC 670, an industrial panel PC designed for human-machine interface (HMI) and control applications. This unit features a 12-inch TFT touch display and comes in a standard configuration including a 20 GB hard drive, 256 MB of RAM, and a Pentium III 500 MHz CPU. It is powered by a 115-230 V input and includes a U.S. mains cable. The system is pre-installed with a German version of Windows 98, making it suitable for integration into existing industrial automation systems requiring legacy software support.

Features

  • 12-inch TFT Touch Display
  • 20 GB Hard Drive (Standard Configuration)
  • 256 MB RAM
  • Pentium III 500 MHz CPU
  • 115-230 V AC Power Input (U.S. Mains Cable included)
  • Pre-installed Windows 98 (German version)

Applications

The SIMATIC Panel PC 670 is typically deployed in industrial environments for tasks such as:
  • Machine operation and control
  • Process visualization and monitoring
  • Data acquisition and display
  • Supervisory control and data acquisition (SCADA) interfaces
  • Operator HMI stations in manufacturing, process, and infrastructure automation

Technical Specifications

Parameter Value
Brand Siemens
Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Product Type PC panels
Product Phase Obsolete
Display Type 12" TFT Touch Display
Hard Drive Capacity 20 GB
RAM 256 MB
CPU Pentium III 500 MHz
Power Input 115-230 V
Operating System Windows 98 (German)
Shipping Weight 4.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Safety First: Ensure all power to the installation area is de-energized and locked out before beginning any work.
  2. Mounting: Securely mount the panel PC into a prepared panel cutout, ensuring proper sealing to maintain environmental protection ratings.
  3. Power Connection: Connect the 115-230 V AC power supply using the provided U.S. mains cable. Verify correct voltage and grounding.
  4. Peripheral Connections: Connect any necessary industrial peripherals (e.g., keyboards, mice, network cables) to the appropriate ports.
  5. Grounding: Ensure the panel PC chassis is properly grounded to the industrial control panel's protective earth.
  6. Environmental Considerations: Verify that the operating environment's temperature, humidity, and vibration levels are within the system's specified limits.
  7. Power Up: After all connections are verified, re-energize the power supply and allow the system to boot.

FAQ

What is the display size and type of the 6AV7612-0AA32-0BE0?

It features a 12-inch TFT touch display, suitable for interactive industrial HMI applications.

What operating system is pre-installed on this Panel PC?

The unit comes with Windows 98 (German version) pre-installed, supporting legacy industrial software.

What are the primary hardware specifications of this SIMATIC Panel PC?

It includes a Pentium III 500 MHz CPU, 256 MB of RAM, and a 20 GB hard drive.

What power input does the 6AV7612-0AA32-0BE0 require?

The Panel PC operates on a 115-230 V AC power supply and includes a U.S. mains cable.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...