Siemens

Siemens 6AV7612-0AE10-0BF0 SIMATIC Panel PC 670

SKU 6AV7612-0AE10-0BF0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7612-0AE10-0BF0

  • Country of origin:Germany

  • Product Type: PC Panel

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: Corrections Applied: none

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7612-0AE10-0BF0 is a SIMATIC Panel PC 670, an industrial panel personal computer designed for human-machine interface (HMI) and control applications. This unit features a 12-inch TFT touch display, providing an interactive interface for operators. It comes equipped with a standard configuration including a 40 GB hard drive, 64 MByte RAM, and a Celeron 300 MHz CPU. The system is configured for 115-230 V power input and includes a U.S. mains cable, with Windows 98 English pre-installed, making it suitable for integration into existing industrial automation environments requiring legacy system compatibility.

Features

  • 12-inch TFT Touch Display
  • Celeron 300 MHz CPU
  • 64 MByte RAM
  • 40 GB Hard Drive
  • 115-230 V Power Input (U.S. Mains Cable)
  • Pre-installed Windows 98 English Operating System

Applications

The SIMATIC Panel PC 670 is typically deployed in industrial settings for:

  • Process visualization and control
  • Human-Machine Interface (HMI) operations
  • Data acquisition and monitoring
  • Machine control and automation
  • Integration into legacy systems requiring Windows 98 compatibility

Technical Specifications

Brand Siemens
Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Product Type PC panels
Product Phase Obsolete
Display Type 12" TFT Touch Display
CPU Celeron 300 MHz
RAM 64 MByte
Hard Drive 40 GB
Operating System Windows 98 English
Power Supply 115-230 V (U.S. Mains Cable)
Shipping Weight 4.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. De-energize System: Ensure all power to the control cabinet or mounting location is disconnected and locked out before beginning installation.
  2. Mounting: Securely mount the Panel PC into the designated panel cutout or enclosure, ensuring proper ventilation clearances as specified by the system integrator.
  3. Power Connection: Connect the 115-230 V AC power supply to the appropriate terminal block on the Panel PC. Verify correct voltage and polarity before applying power.
  4. Grounding: Establish a robust protective earth (PE) connection to the Panel PC chassis to ensure electrical safety and minimize electromagnetic interference.
  5. Peripheral Connections: Connect any required peripherals such as keyboards, mice, or external storage devices to the available ports.
  6. Cable Routing: Route all cables to prevent strain, sharp bends, and interference with other components. Use cable ties and conduits where appropriate.
  7. System Startup: After all connections are verified, re-energize the system and power on the Panel PC. Monitor for proper boot-up and functionality.

FAQ

What is the display size and type of the 6AV7612-0AE10-0BF0?

The unit features a 12-inch TFT touch display.

What operating system is pre-installed on this Panel PC?

It comes with Windows 98 English pre-installed.

What are the main processing specifications of this model?

The Panel PC is equipped with a Celeron 300 MHz CPU, 64 MByte RAM, and a 40 GB hard drive.

What is the power supply requirement for the 6AV7612-0AE10-0BF0?

It requires a 115-230 V AC power supply and includes a U.S. mains cable.

Is the Siemens 6AV7612-0AE10-0BF0 still actively manufactured?

No, this product is listed as obsolete by the manufacturer.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...