Siemens

Siemens 6AV7612-0AE12-0BJ0 SIMATIC Panel PC 670 Panel PC

SKU 6AV7612-0AE12-0BJ0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7612-0AE12-0BJ0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4000g

  • Dimensions: 400 x 300 x 150 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This device is a Siemens 6AV7612-0AE12-0BJ0 SIMATIC Panel PC 670, designed for human-machine interface (HMI) and control applications. It features a 12-inch TFT touch display and is powered by a Pentium III 500 MHz CPU. This standard configuration includes 64 MB of RAM, a 40 GB hard drive, and comes pre-installed with the Windows NT 4.0 English operating system. The unit is designed for a 115-230V AC power supply and includes a U.S. mains cable. Please note, this model is classified as an obsolete product, making it suitable for direct replacement in existing legacy systems.

Features

  • 12-inch TFT color display with integrated touch screen
  • Intel Pentium III processor operating at 500 MHz
  • Equipped with 64 MB of system RAM
  • Includes a 40 GB internal hard drive for storage
  • Pre-loaded with Windows NT 4.0 (English version)
  • Wide input voltage range of 115-230V AC

Applications

  • Operator control and monitoring stations
  • Process visualization and data acquisition
  • Machine-level HMI for manufacturing lines
  • Replacement unit for legacy automation systems
  • Industrial data logging and reporting

Technical Specifications

Specification Value
Manufacturer Siemens
Part Number 6AV7612-0AE12-0BJ0
Product Range SIMATIC Panel PC
Series PC670
Display 12-inch TFT Touch Display
Processor (CPU) Pentium III 500 MHz
Memory (RAM) 64 MB
Storage 40 GB Hard Drive (HD)
Operating System Windows NT 4.0 (English)
Power Supply 115-230 V (AC)
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimated)
Package Dimensions (Calculated) 400 x 300 x 150 mm

Installation Guidelines

CRITICAL WARNING: Electrical Hazard. Disconnect and lock out all power sources before installation or servicing. Installation must be performed by qualified personnel familiar with industrial control panel standards and practices. Failure to comply can result in severe injury or equipment damage.
  1. 1
    Prepare Panel Cutout: Verify the mounting panel has a clean, flat, and appropriately sized cutout according to the device's physical dimensions. Ensure the panel thickness is within the specified tolerance for the mounting clamps.
  2. 2
    Mount the Unit: Insert the Panel PC into the cutout from the front of the panel. Secure it from the rear using the provided mounting clamps, tightening them evenly to ensure a uniform seal against the panel gasket. Do not over-torque the clamps.
  3. 3
    Connect Protective Earth (PE): Connect the chassis to the control panel's protective earth ground using a low-impedance conductor. A reliable ground connection is critical for safety and noise immunity.
  4. 4
    Connect Power Supply: Connect the 115-230V AC mains cable to the unit's power input terminal. Ensure the source voltage matches the device rating. Route power cables separately from signal and communication wiring.
  5. 5
    Connect Peripherals: Connect any required communication cables (e.g., Ethernet, serial) and I/O devices. Ensure all connectors are fully seated and secured.
  6. 6
    Final Checks and Power-Up: After verifying all connections are correct and secure, remove the lockout/tagout and re-apply power to the panel. Observe the device during its boot sequence to confirm normal operation.

FAQ

What operating system is installed on the 6AV7612-0AE12-0BJ0?

This Panel PC comes pre-installed with Windows NT 4.0, English version.

Is this a current product from Siemens?

No, the 6AV7612-0AE12-0BJ0 is classified as an obsolete product. It is primarily intended for use as a spare part or direct replacement in existing systems that utilize this specific model.

What are the main hardware specifications of this unit?

The unit is configured with a 12-inch TFT touch display, a Pentium III 500 MHz CPU, 64 MB of RAM, and a 40 GB hard drive.

What is the required input power for this Panel PC?

This device operates on a wide input voltage range of 115-230V AC. The package includes a U.S. mains cable.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.