Description
The Siemens 6AV7612-0AE22-0CE0 is a SIMATIC Panel PC 670, an integrated human-machine interface (HMI) and industrial computer. This unit features a 12-inch TFT touch display for operator interaction and is powered by a Pentium III 500 MHz CPU. It is configured with 128 MB of RAM and a 40 GB hard drive, pre-installed with a German-language version of Windows 98. Designed for panel mounting, this device supports a wide input voltage range and is intended for industrial control and visualization applications. Please note this model is classified as an obsolete product, making it suitable for legacy system maintenance and spare parts inventory.
Features
- Integrated 12-inch TFT color display with touch functionality.
- Powered by an Intel Pentium III processor operating at 500 MHz.
- Equipped with 128 MB of system RAM.
- Includes a 40 GB internal hard disk drive for storage.
- Flexible power supply input range of 115-230V AC.
- Pre-loaded with Windows 98 operating system (German language).
Applications
- Machine-level operator control and monitoring.
- Process visualization and data acquisition in manufacturing facilities.
- Supervisory control systems in factory automation.
- Replacement unit for maintaining existing legacy automation systems.
Technical Specifications
| Specification |
Value |
| Manufacturer |
Siemens |
| Product Series |
SIMATIC Panel PC 670 |
| Part Number |
6AV7612-0AE22-0CE0 |
| Product Lifecycle Phase |
Obsolete |
| Display Type |
12-inch TFT Touch Display |
| CPU |
Pentium III, 500 MHz |
| Memory (RAM) |
128 MB |
| Storage |
40 GB Hard Drive (HD) |
| Operating System |
Windows 98 (German) |
| Power Supply |
115-230 V AC (with European mains cable) |
| Shipping Weight |
4.00 kg |
| Country of Origin |
Germany (Estimate) |
| Package Dimensions (Calculated) |
45 cm x 35 cm x 20 cm (Estimate) |
| Harmonized Tariff Code |
85371091 |
| ECCN |
N (No License Required) |
Installation Guidelines
CRITICAL WARNING: Hazardous voltages are present. Installation must be performed by qualified personnel only. Failure to de-energize equipment before installation can result in severe injury or death. Always adhere to local lockout/tagout (LOTO) procedures.
-
1
De-energize the main control panel or cabinet. Verify the absence of voltage using a properly rated test instrument before proceeding.
-
2
Ensure the panel cutout dimensions are correct for the PC 670 chassis. Clean the mounting surface to ensure a proper seal.
-
3
Insert the Panel PC into the cutout and secure it using the provided mounting clamps. Tighten clamps evenly to the manufacturer's specified torque to prevent chassis distortion.
-
4
Connect the protective earth (PE) or grounding conductor to the designated terminal on the chassis. This is a critical safety connection.
-
5
Connect the AC mains power cable to the unit's power input connector. Ensure the source voltage matches the 115-230V AC rating.
-
6
Connect all required communication and I/O cables. Ensure proper cable strain relief and routing away from high-voltage conductors.
-
7
After a final inspection of all connections, close the cabinet door, remove the lockout/tagout device, and re-energize the panel to commission the unit.