Siemens

Siemens 6AV7612-0AF20-0CF0 SIMATIC Panel PC 670

SKU 6AV7612-0AF20-0CF0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7612-0AF20-0CF0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 45 x 35 x 20 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This is a Siemens 6AV7612-0AF20-0CF0 SIMATIC Panel PC 670, an integrated human-machine interface (HMI) designed for industrial control and visualization applications. This unit features a 12-inch TFT touch display, powered by an Intel Celeron 300 MHz processor. It is configured with 128 MB of RAM, a 40 GB hard drive, and an integrated CD-ROM drive. The system comes pre-installed with the Windows 98 operating system (English version) and includes a European mains cable for operation on 115-230V AC power sources. As an obsolete product, it serves as a direct replacement for existing systems to maintain operational continuity.

Features

  • 12-inch TFT color display with integrated touchscreen
  • Intel Celeron 300 MHz processor
  • 128 MB of system RAM
  • 40 GB internal hard drive (HD)
  • Integrated CD-ROM optical drive
  • Pre-installed with Windows 98 (English)
  • Includes European mains power cable

Applications

  • Legacy machine control and visualization
  • Process monitoring and data acquisition
  • Direct replacement for failed units in existing control panels
  • Industrial automation systems running on Windows 98 platforms

Technical Specifications

Category Detail
General
Brand Siemens
Model 6AV7612-0AF20-0CF0
Series SIMATIC Panel PC 670
Product Type Panel PC
Product Status Obsolete
Hardware
Processor Intel Celeron 300 MHz
Memory (RAM) 128 MB
Storage 40 GB Hard Drive (HD)
Optical Drive CD-ROM
Display
Type TFT with Touchscreen
Size 12 inch
Software
Operating System Windows 98 (English)
Electrical
Input Voltage 115 - 230 V AC
Logistics & Compliance
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimate)
Manufacturer Siemens
Package Dimensions (Calculated) 45 x 35 x 20 cm

Installation Guidelines

CRITICAL WARNING: Hazardous voltages are present. Installation must be performed by qualified personnel only. Failure to follow safety procedures can result in equipment damage, severe injury, or death.
  1. 1 De-energize the control cabinet and apply Lockout/Tagout (LOTO) procedures before beginning any work. Verify the absence of voltage.
  2. 2 Confirm the panel cutout dimensions are compatible with the Panel PC 670 chassis. Ensure the mounting surface is clean, flat, and free of debris.
  3. 3 Use appropriate Electrostatic Discharge (ESD) precautions, such as a grounded wrist strap, when handling the unit.
  4. 4 Carefully insert the Panel PC into the cutout from the front of the panel. Secure it from the rear using the provided mounting clamps, tightening them evenly to ensure a proper seal.
  5. 5 Connect the mains power cable to a properly grounded and rated power source. Ensure the source voltage matches the 115-230V AC rating.
  6. 6 Connect all required communication, peripheral, and I/O cables. Ensure all connections are secure.
  7. 7 After clearing the work area, remove LOTO devices and re-energize the cabinet. Power on the Panel PC and verify correct system boot and application functionality.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...