Siemens

Siemens 6AV7613-0AB30-0AF0 SIMATIC Panel PC 670 Panel PC

SKU 6AV7613-0AB30-0AF0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7613-0AB30-0AF0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 45 cm x 35 cm x 15 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This is a SIMATIC Panel PC 670 from Siemens, model 6AV7613-0AB30-0AF0, designed for industrial human-machine interface (HMI) and control applications. This unit features a 12-inch TFT display and is powered by an Intel Celeron 300 MHz CPU. The standard configuration includes 256 MB of RAM, a 20 GB hard drive, and an integrated CD-ROM drive. It operates on a 24 V DC power supply and comes pre-installed with the Windows 98 operating system in English. Please note that this product is considered obsolete by the manufacturer.

Features

  • 12-inch TFT color display
  • Intel Celeron 300 MHz processor
  • 256 MB RAM for application processing
  • 20 GB internal hard drive for data and application storage
  • Integrated CD-ROM drive for software installation
  • Operates on a standard 24 V DC industrial power supply
  • Pre-installed with Windows 98 (English language)

Applications

  • Operator control and monitoring stations
  • Process visualization and data acquisition (SCADA)
  • Machine-level data logging and analysis
  • Factory automation and plant floor information systems

Technical Specifications

Specification Value
Brand Siemens
Model 6AV7613-0AB30-0AF0
Product Series SIMATIC Panel PC 670
Product Type Panel PC
Display Size 12 inch
Display Type TFT
Processor (CPU) Celeron 300 MHz
Memory (RAM) 256 MB
Storage 20 GB Hard Drive (HD)
Optical Drive CD-ROM
Power Supply 24 V DC
Operating System Windows 98 (English)
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimated)
Manufacturer Siemens
Package Dimensions (Calculated) 45 cm x 35 cm x 15 cm (Estimated)

Installation Guidelines

CRITICAL WARNING: RISK OF ELECTRIC SHOCK

Disconnect all power sources and follow Lockout/Tagout (LOTO) procedures before installation or servicing. Installation must be performed by qualified personnel only. Failure to comply can result in severe injury or death.

  1.   1 Prepare EnclosureEnsure the control cabinet or panel has a clean, flat, and correctly sized cutout for the PC. Verify that the mounting surface meets IP/NEMA rating requirements if applicable.
  2.   2 Mount the UnitInsert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps, tightening them evenly to ensure a proper seal against the gasket. Do not overtighten.
  3.   3 Connect Protective Earth (PE)Connect a low-impedance protective earth conductor to the designated PE terminal on the unit's chassis. This is critical for operator safety and noise immunity.
  4.   4 Connect Power SupplyConnect the 24 V DC power supply to the power input terminals, observing correct polarity. Use appropriately sized conductors and ensure the power source is stable and within the specified voltage range.
  5.   5 Connect Peripherals and NetworkConnect any required peripherals such as keyboards, mice, and network cables to the appropriate ports. Ensure all cables are securely fastened and routed to prevent strain or interference.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...