Description

The Siemens 6AV7612-0AF32-0CH0 is a SIMATIC Panel PC 670, an industrial personal computer designed for demanding automation environments. This unit features a 12-inch TFT Touch Display, providing an interactive interface for operators. It comes with a standard configuration including a 40 GB Hard Drive, a CD-ROM drive, and 256 MB of RAM. The system is powered by a Pentium III 500 MHz CPU and operates on a 115-230 V European mains cable. Pre-installed with Windows NT 4.0 German, this panel PC is engineered for reliable operation in industrial control and monitoring applications.

Features

  • 12-inch TFT Touch Display
  • Pentium III 500 MHz CPU
  • 256 MB RAM
  • 40 GB Hard Drive and CD-ROM
  • 115-230 V AC Power Input
  • Pre-installed Windows NT 4.0 German operating system
  • Designed for industrial environments

Applications

The SIMATIC Panel PC 670 is suitable for a variety of industrial automation applications, including:

  • Machine operation and control
  • Process visualization and monitoring
  • Data acquisition and logging
  • Human-Machine Interface (HMI) tasks
  • Production line management
  • Building automation systems

Technical Specifications

Attribute Value
Brand Siemens
Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Type of Product PC panels
Display Type 12" TFT Touch Display
CPU Pentium III 500 MHz
RAM 256 MB
Storage 40 GB HD + CD-ROM
Power Supply 115-230 V (European Mains Cable)
Operating System Windows NT 4.0 German
Product Phase Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Power De-energization: Ensure all power to the installation area is disconnected and locked out before beginning any work.
  2. Mounting: Securely mount the panel PC into a prepared panel cutout. Ensure proper sealing to maintain the enclosure's IP rating, if applicable.
  3. Power Connection: Connect the 115-230 V AC mains cable to a suitable, protected power source. Verify correct voltage and grounding.
  4. Grounding: Establish a robust protective earth (PE) connection to the panel PC chassis to ensure electrical safety and minimize electromagnetic interference.
  5. Peripheral Connections: Connect any required peripherals such as keyboards, mice, or external storage devices to the appropriate ports.
  6. Network Connection: If network connectivity is required, connect the Ethernet cable to the designated port.
  7. Environmental Considerations: Ensure the installation environment meets the specified temperature, humidity, and vibration requirements for industrial PC operation.
  8. Power-Up: After all connections are verified, re-energize the power supply and power on the panel PC.

FAQ

What operating system is pre-installed on the Siemens 6AV7612-0AF32-0CH0?

The panel PC comes with Windows NT 4.0 German pre-installed.

What is the display size and type of this SIMATIC Panel PC?

It features a 12-inch TFT Touch Display.

What are the power requirements for the 6AV7612-0AF32-0CH0?

The unit operates on a 115-230 V AC European mains cable.

What is the CPU and memory configuration?

It is equipped with a Pentium III 500 MHz CPU and 256 MB of RAM.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...