Siemens

Siemens 6AV7612-2BB12-0CH0 SIMATIC Panel PC 670

SKU 6AV7612-2BB12-0CH0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7612-2BB12-0CH0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 0.10 x 0.10 x 0.10 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7612-2BB12-0CH0 is a SIMATIC Panel PC 670, an industrial panel computer designed for visualization and control tasks in automation environments. This unit features a 12-inch TFT touch display, making it suitable for operator interface applications. It comes pre-equipped with a PROTOOL/PRO Runtime License, supporting 256 power tags, and includes a 20 GB hard drive, a CD-ROM drive, and 64 MB of RAM. The system is powered by a Pentium III 500 MHz CPU and operates on 115-230 V European mains power, running the Windows NT 4.0 German operating system.

Features

  • 12-inch TFT Touch Display
  • Integrated PROTOOL/PRO Runtime License (256 Power Tags)
  • 20 GB Hard Drive and CD-ROM
  • 64 MB RAM
  • Pentium III 500 MHz CPU
  • 115-230 V Power Supply
  • Pre-installed Windows NT 4.0 German Operating System

Applications

The Siemens SIMATIC Panel PC 670 is typically deployed in industrial settings requiring a robust human-machine interface (HMI) for process visualization, data acquisition, and machine control. Common applications include:
  • Machine operation and monitoring
  • Process control and supervision in manufacturing plants
  • Building automation systems
  • Logistics and material handling systems
  • Data entry and display in harsh industrial environments

Technical Specifications

Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Product Type PC panels
Display Type 12" TFT Touch Display
Included Software PROTOOL/PRO Runtime License (256 Power Tags)
Storage 20 GB HD + CD-ROM
RAM 64 MBYTE
CPU Pentium III 500 MHz
Power Supply 115-230 V
Mains Cable Type Europ.
Operating System Windows NT 4.0 German
Product Phase Obsolete
Package Dimensions (Calculated) 0.10 x 0.10 x 0.10 cm
Shipping Weight 12.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

Proper installation is crucial for the reliable operation of the SIMATIC Panel PC 670.
  1. De-energize System: Before commencing any installation work, ensure that all power to the system and associated components is de-energized and locked out to prevent accidental startup.
  2. Mounting: Mount the panel PC securely into a prepared panel cutout. Ensure adequate clearance for ventilation and cable routing at the rear.
  3. Power Connection: Connect the 115-230 V AC power supply using the appropriate European mains cable. Verify correct voltage and polarity before applying power.
  4. Grounding: Establish a robust protective earth (PE) connection to the panel PC chassis to ensure electrical safety and minimize electromagnetic interference.
  5. Peripheral Connections: Connect any required peripherals such as keyboards, mice, or external storage devices to the available ports.
  6. Cable Routing: Route power and data cables separately to avoid interference. Secure cables to prevent strain and accidental disconnection.
  7. Initial Power-Up: After all connections are verified, re-energize the system. Observe the boot sequence and ensure the Windows NT 4.0 operating system loads correctly.
  8. Software Configuration: Configure the PROTOOL/PRO Runtime application as required for the specific automation task.

FAQ

What operating system is pre-installed on the 6AV7612-2BB12-0CH0?

The Siemens 6AV7612-2BB12-0CH0 comes with Windows NT 4.0 German pre-installed.

What type of display does this Panel PC feature?

It features a 12-inch TFT touch display, suitable for interactive operator control.

What is the CPU speed of the SIMATIC Panel PC 670?

The unit is equipped with a Pentium III processor running at 500 MHz.

Is a PROTOOL/PRO Runtime License included with this Panel PC?

Yes, a PROTOOL/PRO Runtime License with support for 256 power tags is included.

What is the power supply requirement for this device?

The Panel PC operates on a 115-230 V AC power supply and includes a European mains cable.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.