Siemens

Siemens 6AV7612-0AF20-0AH0 SIMATIC Panel PC 670 Panel PC

SKU 6AV7612-0AF20-0AH0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7612-0AF20-0AH0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 45 x 35 x 20 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This is a Siemens 6AV7612-0AF20-0AH0, a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) applications. This unit features a 12-inch TFT touch display and is powered by a 300 MHz Celeron processor. The standard configuration includes 128 MB of RAM, a 40 GB hard drive, and an integrated CD-ROM drive. It operates on a 24 V DC power supply and comes pre-installed with the Windows NT 4.0 operating system in German. This model is part of the legacy PC670 series, suitable for maintaining existing systems.

Features

  • 12-inch TFT color display with integrated touch screen
  • Intel Celeron processor operating at 300 MHz
  • 128 MB of installed system RAM
  • 40 GB internal hard drive for data and application storage
  • Integrated CD-ROM optical drive
  • Requires a 24 V DC nominal power input
  • Pre-loaded with Windows NT 4.0 (German language version)

Applications

  • Machine-level operator control and monitoring
  • Process visualization and data acquisition
  • Supervisory control systems in manufacturing environments
  • Replacement unit for existing SIMATIC PC 670 installations

Technical Specifications

Specification Value
Manufacturer Siemens
Part Number 6AV7612-0AF20-0AH0
Series SIMATIC Panel PC 670
Product Type Panel PC
Display 12-inch TFT Touch Display
Processor (CPU) Celeron 300 MHz
Memory (RAM) 128 MB
Storage 40 GB Hard Drive (HD)
Optical Drive CD-ROM
Power Supply 24 V DC
Operating System Windows NT 4.0 (German)
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimate)
Package Dimensions (Calculated) 45 x 35 x 20 cm

Installation Guidelines

CRITICAL WARNING

Disconnect all power sources before installation or maintenance. This device operates on DC voltage which can cause severe injury or death. Installation must be performed by qualified personnel only. Failure to properly ground the chassis may result in electrical noise, unpredictable operation, and a safety hazard.

  1. 1 Prepare Mounting Location: Ensure the panel cutout dimensions are correct and the mounting surface is clean, flat, and can support the weight of the unit. Verify adequate clearance for ventilation and cable routing at the rear of the panel.
  2. 2 Mount the Unit: Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps. Tighten the clamps evenly to ensure a consistent seal against the panel gasket. Do not overtighten.
  3. 3 Connect Protective Earth (PE): Connect a low-impedance protective earth conductor to the designated grounding terminal on the PC chassis. This is critical for both safety and noise immunity. Use the largest wire gauge feasible.
  4. 4 Connect Power Supply: Connect the 24 V DC power source to the power input terminals. Verify correct polarity (+/-) before energizing the circuit. Use appropriately sized wiring for the load and distance from the power supply.
  5. 5 Connect Peripherals: Connect all required communication cables (e.g., Ethernet, serial) and I/O devices. Ensure all connectors are fully seated and secured. Power on the unit and verify correct system boot and operation.

FAQ

What operating system is installed on the 6AV7612-0AF20-0AH0?

This Panel PC comes pre-installed with Windows NT 4.0 in the German language version.

What are the power supply requirements for this unit?

The device requires a 24 V DC power source for operation.

Does this model include a touch screen?

Yes, it is equipped with a 12-inch TFT touch display for operator interaction.

What are the memory and storage specifications?

This configuration includes 128 MB of RAM, a 40 GB hard drive, and an integrated CD-ROM drive.

Is this a current product from Siemens?

No, the product lifecycle status for this model is listed as Obsolete. It is suitable for spares or maintaining existing systems.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.