Siemens

Siemens 6AV7613-0AB10-0CH0 SIMATIC Panel PC 670

SKU 6AV7613-0AB10-0CH0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7613-0AB10-0CH0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 35.0 cm x 25.0 cm x 25.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This is a Siemens 6AV7613-0AB10-0CH0, a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control panel applications. This specific configuration features a 12-inch TFT display, an Intel Celeron 300 MHz CPU, 64 MB of RAM, and a 20 GB hard drive. It includes an integrated CD-ROM drive and is pre-installed with the Windows NT 4.0 operating system in German. This unit is classified as an obsolete product, making it suitable for spare parts inventory or maintaining legacy automation systems.

Features

  • 12-inch TFT color display for process visualization.
  • Powered by an Intel Celeron 300 MHz processor.
  • Equipped with 64 MB of RAM and a 20 GB hard drive.
  • Integrated CD-ROM drive for software installation and data access.
  • Pre-installed with Windows NT 4.0 (German language version).
  • Designed for 115-230V AC power input.

Applications

  • Replacement unit for existing SIMATIC PC 670 installations.
  • Machine-level HMI and data visualization.
  • Supervisory control and data acquisition (SCADA) nodes.
  • Process control panels in manufacturing and production lines.

Technical Specifications

Category Detail
General Information
Manufacturer Siemens
Product Series SIMATIC Panel PC 670
Part Number 6AV7613-0AB10-0CH0
Product Type Panel PC
Product Lifecycle Status Obsolete
Hardware Configuration
Display 12-inch TFT
Processor (CPU) Intel Celeron 300 MHz
Memory (RAM) 64 MB
Storage 20 GB Hard Drive (HD)
Optical Drive CD-ROM
Software
Operating System Windows NT 4.0 (German)
Electrical
Input Voltage 115-230 VAC
Included Cable European Mains Cable
Logistics and Compliance
Shipping Weight 12.00 kg
Package Dimensions (Calculated) 35.0 cm x 25.0 cm x 25.0 cm
Commodity Code 85371091
ECCN N (Not subject to control)
Country of Origin Germany (Estimate)

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Disconnect all power sources before installation or servicing. This equipment is intended for use by qualified personnel only. Failure to de-energize the system can result in severe injury or death. As an obsolete device, ensure all existing application software and data are backed up before replacement.

  1. 1 Ensure the control cabinet or panel is completely de-energized and locked out (LOTO). Verify zero-energy state with a calibrated multimeter.
  2. 2 Verify the panel cutout dimensions match the PC 670 chassis requirements. Clean the mounting surface to ensure a proper seal.
  3. 3 Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps, tightening them evenly to the manufacturer's specified torque to avoid chassis distortion.
  4. 4 Connect a low-impedance protective earth (PE) conductor to the designated grounding terminal on the chassis. This connection must be made first.
  5. 5 Connect the 115-230 VAC mains cable to the power supply input. Ensure the source voltage matches the unit's rating.
  6. 6 Connect all required peripherals, such as network cables, keyboards, mice, and any serial or parallel devices.
  7. 7 After removing LOTO and closing the cabinet, re-apply power and verify that the Panel PC boots correctly into the Windows NT operating system.

FAQ

What operating system is installed on this device?

This unit comes pre-installed with Windows NT 4.0 in German.

What are the core hardware specifications?

It features an Intel Celeron 300 MHz CPU, 64 MB of RAM, a 20 GB hard drive, and a 12-inch TFT display.

Is this product still in production?

No, the 6AV7613-0AB10-0CH0 is an obsolete product, typically used for maintaining or repairing existing legacy systems.

What is the required input voltage?

The unit is specified for a 115-230V AC power supply and includes a European mains cable.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.