Siemens

Siemens 6AV7614-0AA10-0BG0 SIMATIC Panel PC 670 Panel PC

SKU 6AV7614-0AA10-0BG0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7614-0AA10-0BG0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 45 x 35 x 15 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7614-0AA10-0BG0 is a SIMATIC Panel PC 670 designed for human-machine interface (HMI) and control tasks in industrial environments. This unit features a 15-inch TFT touch display and is powered by a Celeron 300 MHz CPU. It is configured with 64 MB of RAM and a 20 GB hard drive. The system comes pre-installed with a multi-language version of Windows 2000 and is supplied with a U.S. mains cable for operation on 115-230V power sources.

Features

  • 15-inch TFT color touch display for operator interaction.
  • Celeron 300 MHz processor for control and visualization tasks.
  • Equipped with 64 MB RAM and a 20 GB hard drive.
  • Pre-loaded with Windows 2000 operating system (English, German, French, Italian, Spanish).
  • Supports a wide input voltage range of 115-230V AC.
  • Includes a U.S. standard mains power cable.

Applications

  • Process visualization and control
  • Machine-level HMI stations
  • Data acquisition and logging
  • Factory floor information systems
  • Supervisory control in manufacturing lines

Technical Specifications

Specification Value
Manufacturer Siemens
Model Number 6AV7614-0AA10-0BG0
Product Series SIMATIC Panel PC 670
Display Type 15-inch TFT Touch Display
Processor (CPU) Celeron 300 MHz
Memory (RAM) 64 MB
Storage 20 GB Hard Drive (HD)
Input Voltage 115-230V AC
Operating System Windows 2000 Multi-Language (EN, GER, FR, IT, SP)
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimate)
Package Dimensions (Calculated) 45 x 35 x 15 cm

Installation Guidelines

CRITICAL WARNING: Hazardous voltages are present. Installation must be performed by qualified personnel only. Failure to de-energize equipment and follow Lockout/Tagout (LOTO) procedures before installation can result in severe injury or death.
  1. 1
    Site Preparation: Ensure the panel cutout dimensions match the PC 670's mounting requirements. Verify that the mounting surface is flat, rigid, and can support the weight of the unit. Maintain adequate clearance around the unit for ventilation.
  2. 2
    Mounting: Insert the Panel PC into the prepared cutout from the front. Secure the unit from the rear using the provided mounting clamps, tightening them evenly to ensure a proper seal against the panel gasket. Do not overtighten.
  3. 3
    Grounding: Connect the chassis grounding terminal to the control cabinet's protective earth (PE) bus bar using a low-impedance conductor. A reliable ground connection is essential for operator safety and noise immunity.
  4. 4
    Power Connection: With the main power source locked out, connect the provided mains cable to the unit's power input. Ensure the source voltage (115-230V AC) matches the equipment's rating. Route the power cable away from sensitive signal wiring.
  5. 5
    Final Checks: Connect all required communication and I/O cables. Verify all connections are secure before removing LOTO devices and applying power to the cabinet.

FAQ

What operating system is installed on the 6AV7614-0AA10-0BG0?

This Panel PC comes pre-installed with a multi-language version of Windows 2000, which includes English, German, French, Italian, and Spanish.

What is the display size and type for this unit?

The unit is equipped with a 15-inch TFT touch display for operator interface and control.

What is the product lifecycle status of this Panel PC?

The Siemens 6AV7614-0AA10-0BG0 is classified as an obsolete product. It is suitable for spare part replacement in existing systems.

What are the power requirements for this device?

This Panel PC operates on an input voltage of 115-230V AC and is supplied with a U.S. mains power cable.

What are the core processing and memory specifications?

It features a Celeron 300 MHz CPU, 64 MB of RAM, and a 20 GB hard drive for storage.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.