Siemens

Siemens 6AV7614-0AA20-0BG0 SIMATIC Panel PC 670

SKU 6AV7614-0AA20-0BG0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7614-0AA20-0BG0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 45 cm x 40 cm x 25 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7614-0AA20-0BG0 is a SIMATIC Panel PC 670, designed for industrial human-machine interface (HMI) and control applications. This unit features a 15-inch TFT touch display, providing an interactive interface for operators. It comes equipped with a standard configuration including a Celeron 300 MHz CPU, 128 MB of RAM, and a 20 GB hard drive. The panel PC operates on a 115-230 V power supply and includes a U.S. mains cable. It is pre-installed with Windows 2000 Multi-Language, supporting English, German, French, Italian, and Spanish.

Features

  • 15-inch TFT Touch Display
  • Celeron 300 MHz CPU
  • 128 MB RAM
  • 20 GB Hard Drive
  • 115-230 V Power Supply (U.S. Mains Cable included)
  • Pre-installed Windows 2000 Multi-Language (EN, GER, FR, IT, SP)
  • Industrial-grade design for reliable operation

Applications

The SIMATIC Panel PC 670 is suitable for various industrial automation applications, including:

  • Process visualization and control
  • Machine operation and monitoring
  • Data acquisition and logging
  • Supervisory control and data acquisition (SCADA) systems
  • Manufacturing execution systems (MES) interfaces

Technical Specifications

Parameter Value
Manufacturer Siemens
Range SIMATIC Panel PC
Subrange PC670
Product Type Panel PC
Display 15" TFT Touch
CPU Celeron 300 MHz
RAM 128 MBYTE
Hard Drive 20 GB
Power Supply 115-230 V (U.S. Mains Cable)
Operating System Windows 2000 Multi-Language (EN, GER, FR, IT, SP)
Product Phase Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N
Country of Origin Unknown
Package Dimensions (Calculated) 45 cm x 40 cm x 25 cm

Installation Guidelines

  1. Safety First: Ensure all power to the installation area is de-energized and locked out before beginning any work.
  2. Mounting: Mount the panel PC securely into a prepared panel cutout, ensuring proper ventilation clearances around the unit. Use appropriate mounting hardware to prevent vibration and ensure stability.
  3. Power Connection: Connect the supplied U.S. mains cable to the designated power input of the panel PC. Verify the voltage supply matches the 115-230 V requirement of the unit.
  4. Grounding: Establish a reliable protective earth (PE) connection to the panel PC chassis to ensure electrical safety and minimize electromagnetic interference.
  5. Peripheral Connections: Connect any necessary peripherals such as keyboards, mice, or external storage devices to the available ports.
  6. System Startup: After all connections are secure, re-energize the power supply and power on the panel PC. Allow the operating system to boot completely.
  7. Configuration: Configure the Windows 2000 operating system and any application software as required for the specific industrial process.

FAQ

What is the display size and type of the 6AV7614-0AA20-0BG0?

The unit features a 15-inch TFT touch display, providing an interactive interface for industrial applications.

What are the core hardware specifications of this Panel PC?

It includes a Celeron 300 MHz CPU, 128 MB of RAM, and a 20 GB hard drive.

What operating system is pre-installed on the SIMATIC Panel PC 670?

The panel PC comes with Windows 2000 Multi-Language pre-installed, supporting English, German, French, Italian, and Spanish.

What is the required power supply voltage for this unit?

The unit operates on a 115-230 V power supply and includes a U.S. mains cable.

Is the 6AV7614-0AA20-0BG0 still an active product?

According to the product phase information, this model is classified as Obsolete.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.