Siemens 6AV7614-0AF12-0CF0 SIMATIC Panel PC 670

SKU 6AV7614-0AF12-0CF0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7614-0AF12-0CF0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 35.0 x 25.0 x 25.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7614-0AF12-0CF0 is a SIMATIC Panel PC 670 designed for human-machine interface (HMI) and control tasks in industrial environments. This unit integrates a 15-inch TFT touch display, a Pentium III 500 MHz CPU, and 64 MB of RAM into a single panel-mount chassis. It includes a 40 GB hard drive and a CD-ROM drive for data storage and software installation. The system is configured with a 115-230V AC power supply and comes pre-installed with the Windows 98 operating system in English.

Features

  • 15-inch TFT color touch display for operator interaction.
  • Powered by an Intel Pentium III 500 MHz processor.
  • Equipped with 64 MB of system RAM.
  • Includes a 40 GB hard drive and an integrated CD-ROM drive.
  • Wide-range power supply input of 115-230V AC.
  • Pre-installed with Microsoft Windows 98 (English).

Applications

  • Machine-level data visualization and control.
  • Process monitoring in manufacturing and production lines.
  • Supervisory control and data acquisition (SCADA) nodes.
  • Legacy system integration and replacement.

Technical Specifications

Specification Value
Brand Siemens
Model SIMATIC Panel PC 670
Part Number 6AV7614-0AF12-0CF0
Product Status Obsolete
Display Size 15 inch
Display Type TFT Touch Display
Processor (CPU) Pentium III 500 MHz
Memory (RAM) 64 MB
Storage 40 GB Hard Drive (HD)
Optical Drive CD-ROM
Operating System Windows 98 (English)
Input Voltage 115-230 V AC
Shipping Weight 12.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimate)
Manufacturer Siemens
Package Dimensions (Calculated) 35.0 x 25.0 x 25.0 cm

Installation Guidelines

CRITICAL WARNING: Hazardous voltages are present. All installation, wiring, and maintenance must be performed by qualified personnel only. Ensure the main power source is de-energized and locked out/tagged out (LOTO) before beginning any work. Failure to comply can result in severe injury or death.
  1.  1 Prepare the panel cutout according to the manufacturer's dimensional drawings. Ensure the mounting surface is flat, clean, and can support the weight of the unit (12.00 kg).
  2.  2 Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps, tightening them evenly to the specified torque to ensure a proper seal.
  3.  3 Connect a low-impedance protective earth (PE) or functional ground conductor to the designated grounding terminal on the chassis. This is critical for safety and noise immunity.
  4.  4 Connect the 115-230V AC mains power using the provided European mains cable to a properly rated and protected power source. Ensure the voltage matches the supply.
  5.  5 Connect all necessary peripheral devices such as keyboards, mice, and network cables. Power on the unit and verify correct operation of the display and operating system.

FAQ

What operating system is installed on the 6AV7614-0AF12-0CF0?

This Panel PC comes pre-installed with Microsoft Windows 98, English language version.

What is the processor and RAM configuration?

The unit is equipped with an Intel Pentium III 500 MHz processor and 64 MB of RAM.

What is the required input power for this device?

The Siemens Panel PC 670 accepts a wide-range input voltage of 115-230V AC.

Does this model include a touch screen?

Yes, the 6AV7614-0AF12-0CF0 features a 15-inch TFT touch display for operator input.

What is the product lifecycle status of this Panel PC?

This product is classified as 'Obsolete' by the manufacturer, meaning it is no longer in production but may be available as a spare part for existing systems.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.