The Siemens 6AV7614-0AE10-0BF0 is a SIMATIC Panel PC 670, an integrated human-machine interface (HMI) solution for industrial environments. This unit features a 15-inch TFT touch display, a 300 MHz Celeron CPU, 64 MB of RAM, and a 40 GB hard drive. It is configured for a 115-230V AC power supply and comes pre-installed with the Windows 98 operating system in English. This model is suitable for legacy system maintenance and replacement where this specific configuration is required.

Features

  • 15-inch TFT color touch display for operator interaction.
  • Powered by an Intel Celeron processor operating at 300 MHz.
  • Equipped with 64 MB of system RAM.
  • Includes a 40 GB hard drive for operating system and application storage.
  • Pre-loaded with Windows 98 (English version).
  • Supplied with a U.S. mains cable for 115-230V AC power sources.

Applications

  • Legacy manufacturing line control and monitoring.
  • Process visualization in older automation systems.
  • Direct replacement for failed units in existing installations.
  • Data acquisition and logging stations.

Technical Specifications

Specification Value
Manufacturer Siemens
Product Series SIMATIC Panel PC 670
Model Number 6AV7614-0AE10-0BF0
Display Size 15 inch
Display Type TFT Touch Display
Processor (CPU) Celeron 300 MHz
Memory (RAM) 64 MB
Storage 40 GB Hard Drive (HD)
Operating System Windows 98 (English)
Input Voltage 115-230 V AC
Included Cable U.S. Mains Cable
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimate)
Package Dimensions (Calculated) 45 x 35 x 15 cm

Installation Guidelines

CRITICAL WARNING: RISK OF ELECTRIC SHOCK

Disconnect all power sources before installation or servicing. This equipment is intended for use by qualified personnel only. Failure to de-energize the system can result in severe injury or death. Always verify the absence of voltage before proceeding.

  1. 1 Ensure the control cabinet or mounting panel is completely de-energized and locked out according to safety procedures.
  2. 2 Verify that the panel cutout dimensions match the requirements for the Panel PC 670 chassis. Ensure the mounting surface is clean, flat, and free of debris.
  3. 3 Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps, tightening them evenly to ensure a proper seal against the panel gasket. Do not overtighten.
  4. 4 Connect the protective earth (PE) or grounding conductor to the designated terminal on the PC chassis. This is the first electrical connection to be made.
  5. 5 Connect the 115-230V AC power supply using the provided U.S. mains cable to the corresponding power input on the unit.
  6. 6 Connect all necessary communication cables (e.g., Ethernet, serial) and any peripheral devices. Ensure proper cable strain relief and routing to prevent damage.

FAQ

What is the CPU and RAM configuration of this Panel PC?

The 6AV7614-0AE10-0BF0 is equipped with a 300 MHz Celeron processor and 64 MB of system RAM.

What operating system is installed on the device?

This unit comes with the Windows 98 operating system (English edition) pre-installed on its 40 GB hard drive.

What are the display specifications?

It features a 15-inch TFT color display with integrated touch screen functionality for operator input.

Is this Panel PC a current product?

No, the product lifecycle status for this specific model is listed as Obsolete, making it suitable for spare parts or maintaining existing legacy systems.

What power supply is required for this unit?

The Panel PC is designed for a 115-230V AC power source and is supplied with a U.S. mains cable.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.