Description
This is a SIMATIC Panel PC 670, model 6AV7614-0AE30-0BG0, from Siemens. It is an industrial human-machine interface (HMI) designed for panel mounting in automation environments. This standard configuration features a 15-inch TFT touch display, a Celeron 300 MHz CPU, 256 MB of RAM, and a 40 GB hard drive. The unit is pre-installed with a multi-language version of Windows 2000 and is supplied with a U.S. mains cable for operation on 115-230 V AC power sources. Note that this product is considered obsolete by the manufacturer, making it suitable for legacy system maintenance and spare parts inventory.
Features
- 15-inch TFT color display with integrated touch screen
- Powered by a Celeron 300 MHz processor
- Equipped with 256 MB of system RAM
- Includes a 40 GB internal hard drive for storage
- Pre-loaded with Windows 2000 (Multi-language: EN, GER, FR, IT, SP)
- Designed for 115-230 V AC power input
Applications
- Machine-level operator control and monitoring
- Data acquisition and logging in industrial settings
- Supervisory control for small to medium automation cells
- Replacement HMI for legacy systems utilizing the PC 670 platform
Technical Specifications
| Specification |
Value |
| Manufacturer |
Siemens |
| Model Number |
6AV7614-0AE30-0BG0 |
| Product Series |
SIMATIC Panel PC 670 |
| Display Type |
15-inch TFT Touch Display |
| Processor (CPU) |
Celeron 300 MHz |
| Memory (RAM) |
256 MB |
| Storage |
40 GB Hard Drive (HD) |
| Operating System |
Windows 2000 (Multi-language: EN, GER, FR, IT, SP) |
| Power Supply |
115-230 V AC (Supplied with U.S. mains cable) |
| Product Lifecycle Status |
Obsolete |
| Shipping Weight |
4.00 kg |
| Commodity Code |
85371091 |
| ECCN |
N |
| Country of Origin |
Germany (Estimate) |
| Package Dimensions (Calculated) |
50 x 40 x 20 cm |
Installation Guidelines
CRITICAL WARNING: HAZARD OF ELECTRIC SHOCK
Installation must be performed by qualified personnel only. Disconnect and lock out all power sources before accessing the control cabinet or attempting to install this device. Failure to de-energize equipment can result in severe injury or death.
-
1
Ensure the control cabinet is de-energized and verified with a multimeter. Follow all site-specific Lockout/Tagout (LOTO) procedures.
-
2
Verify the panel cutout dimensions match the requirements for the Panel PC 670 chassis. Ensure the mounting surface is clean, flat, and free of debris.
-
3
Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps, tightening them evenly to the manufacturer's specified torque to ensure a proper seal.
-
4
Connect a protective earth (PE) or grounding conductor to the designated chassis terminal. This connection is critical for safety and must be made first.
-
5
Connect the 115-230 V AC mains cable to the power input terminal on the device. Ensure the power source voltage matches the device's rating.
-
6
Connect all required communication and I/O cables (e.g., Ethernet, serial, USB). Secure cables to prevent strain on the connectors.
-
7
After verifying all connections are secure and correct, remove LOTO devices and re-energize the cabinet to commission the Panel PC.