Siemens

Siemens 6AV7615-0AB10-0AF0 SIMATIC Panel PC 670

SKU 6AV7615-0AB10-0AF0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7615-0AB10-0AF0

  • Country of origin:Germany

  • Product Type: PC Panel

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 35.00 x 25.00 x 25.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7615-0AB10-0AF0 is a SIMATIC Panel PC 670, an industrial panel computer designed for human-machine interface (HMI) and control tasks in automation environments. This specific configuration features a 15-inch TFT display, a 20 GB hard disk drive, a CD-ROM drive, and 64 MB of RAM. It is powered by a Celeron 300 MHz CPU, operates on a 24 V DC power supply, and comes with Windows 98 English pre-installed. The SIMATIC Panel PC 670 provides a robust and integrated solution for visualization and data processing directly at the machine or process level.

Features

  • 15-inch TFT Display
  • 20 GB Hard Disk Drive
  • CD-ROM Drive
  • 64 MB RAM
  • Celeron 300 MHz CPU
  • 24 V DC Power Supply
  • Windows 98 English Operating System
  • Integrated Panel PC design

Applications

The Siemens SIMATIC Panel PC 670 is suitable for a range of industrial applications requiring local visualization and control, including:
  • Machine operation and monitoring
  • Process visualization and data acquisition
  • Factory automation systems
  • Building management systems
  • Distributed control systems (DCS) HMI
  • Supervisory control and data acquisition (SCADA) interfaces

Technical Specifications

Brand Siemens
Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Product Type PC panels
Display Type 15" TFT DISPLAY
Hard Disk Drive 20 GB HD
Optical Drive CD-ROM
RAM 64 MBYTE
CPU CELERON 300 MHZ
Power Supply 24 V DC
Operating System WIN98 ENGLISH
Product Phase Obsolete
Package Dimensions (Calculated) 35.00 x 25.00 x 25.00 cm
Shipping Weight 12.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. De-energize System: Before installation, ensure all power to the control cabinet or mounting location is disconnected and secured against accidental re-energization.
  2. Mounting: Securely mount the Panel PC into a prepared panel cutout or enclosure, ensuring proper ventilation clearances as specified by the manufacturer.
  3. Power Connection: Connect the 24 V DC power supply to the designated terminals, observing correct polarity. Verify the power source meets the specified voltage and current requirements.
  4. Grounding: Establish a robust protective earth (PE) connection to the Panel PC chassis to ensure electrical safety and minimize electromagnetic interference.
  5. Peripheral Connections: Connect any necessary peripherals such as keyboards, mice, or external storage devices to the available ports.
  6. Network Connections: If applicable, connect Ethernet cables for network communication to the designated ports.
  7. Cable Routing: Route all cables to prevent strain, abrasion, and interference with other components. Use cable ties and conduits where appropriate.
  8. Environmental Check: Confirm that the operating environment (temperature, humidity, vibration) is within the specified limits for the Panel PC.
  9. Power On: After all connections are verified, re-energize the system and power on the Panel PC.

FAQ

What operating system is pre-installed on the 6AV7615-0AB10-0AF0?

The Siemens 6AV7615-0AB10-0AF0 comes with Windows 98 English pre-installed.

What is the display size of this Panel PC?

This SIMATIC Panel PC features a 15-inch TFT display.

What type of CPU does the PC670 6AV7615-0AB10-0AF0 use?

It is equipped with a Celeron 300 MHz CPU.

What is the power supply requirement for this Panel PC?

The unit requires a 24 V DC power supply for operation.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks