Siemens

Siemens 6AV7615-0AA20-0AH0 SIMATIC Panel PC 670

SKU 6AV7615-0AA20-0AH0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7615-0AA20-0AH0

  • Country of origin:Germany

  • Product Type: PC Panels

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 35.00 x 25.00 x 25.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7615-0AA20-0AH0 is a SIMATIC Panel PC 670, an industrial panel personal computer featuring a 15-inch TFT display. This unit comes in a standard configuration with a Celeron 300 MHz CPU, 128 MB of RAM, and a 20 GB hard drive. It operates on a 24 V DC power supply and is pre-installed with Windows NT 4.0 (German version), making it suitable for human-machine interface (HMI) and control applications in industrial environments.

Features

  • 15-inch TFT display for clear visualization
  • Integrated Celeron 300 MHz CPU
  • 128 MB RAM for system operations
  • 20 GB hard disk drive for data storage
  • Designed for 24 V DC power input
  • Pre-installed with Windows NT 4.0 (German) operating system

Applications

  • Industrial human-machine interface (HMI)
  • Process visualization and control
  • Data acquisition and monitoring systems
  • Machine operation and diagnostics
  • Embedded control applications requiring a display and PC functionality

Technical Specifications

Attribute Value
Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Type of Product PC panels
PLM Product Phase Obsolete
Display Type 15" TFT
CPU Celeron 300 MHz
RAM 128 MB
Hard Drive 20 GB
Operating System Windows NT 4.0 (German)
Power Supply 24 V DC
Package Dimensions (Calculated) 35.00 x 25.00 x 25.00 cm
Shipping Weight 12.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. De-energize System: Before commencing installation, ensure all power to the system and the panel PC's intended mounting location is completely de-energized and locked out according to safety protocols.
  2. Mounting: Securely mount the SIMATIC Panel PC 670 into a control cabinet or panel cutout. Ensure adequate clearance for ventilation and cable routing.
  3. Power Connection: Connect the 24 V DC power supply to the designated terminals, observing correct polarity. Verify the power source meets the specified voltage and current requirements.
  4. Grounding: Establish a proper protective earth (PE) connection to the panel PC's chassis to ensure electrical safety and minimize electromagnetic interference.
  5. Peripheral Connections: Connect any necessary peripherals such as keyboards, mice, or external storage devices to the appropriate ports.
  6. Network/Communication: If applicable, connect network cables to the Ethernet ports for communication with other automation components or control systems.
  7. Cable Management: Route all cables neatly and securely, ensuring they are not subjected to strain or sharp bends. Separate power cables from signal cables to reduce interference.
  8. Power Up: Once all connections are verified, re-energize the system and power on the panel PC. Monitor for proper boot-up and functionality.

FAQ

What is the display size of the Siemens 6AV7615-0AA20-0AH0?

The panel PC is equipped with a 15-inch TFT display.

What operating system is pre-installed on this unit?

It comes with Windows NT 4.0 (German version) pre-installed.

What are the core hardware specifications of this Panel PC?

The unit features a Celeron 300 MHz CPU, 128 MB of RAM, and a 20 GB hard drive.

What is the power supply requirement for the 6AV7615-0AA20-0AH0?

This SIMATIC Panel PC operates on a 24 V DC power supply.

What is the product's current lifecycle status?

The Siemens 6AV7615-0AA20-0AH0 is currently in an obsolete product phase.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.