Description

This is a Siemens 6AV7615-0AB20-0AJ0 SIMATIC Panel PC 670, a panel-mounted industrial computer designed for human-machine interface (HMI) and control applications. This standard configuration features a 15-inch TFT display, an Intel Celeron 300 MHz processor, and 128 MB of RAM. It is equipped with a 20 GB hard drive and an integrated CD-ROM drive for storage and software installation. The unit operates on a 24 VDC power supply and comes pre-installed with the Windows NT 4.0 English operating system. Please note that this product is considered obsolete, making it suitable for maintaining or repairing legacy systems.

Features

  • 15-inch TFT color display
  • Intel Celeron 300 MHz processor
  • 128 MB system RAM
  • 20 GB internal hard drive (HD)
  • Integrated CD-ROM drive
  • Operates on a 24 VDC power supply
  • Pre-installed with Windows NT 4.0 (English)

Applications

  • Legacy HMI visualization stations
  • Process control and monitoring
  • Data acquisition and logging systems
  • SCADA client terminals
  • Machine control interfaces in manufacturing

Technical Specifications

Category Specification
Manufacturer Siemens
Product Series SIMATIC Panel PC
Model PC670
Part Number 6AV7615-0AB20-0AJ0
Display 15-inch TFT
Processor (CPU) Celeron 300 MHz
Memory (RAM) 128 MB
Storage 20 GB Hard Drive (HD)
Optical Drive CD-ROM
Operating System Windows NT 4.0 (English)
Power Supply 24 V DC
Product Lifecycle Status Obsolete
Shipping Weight 12.00 kg
Package Dimensions (Calculated) 35.0 cm x 25.0 cm x 25.0 cm
Commodity Code 85371091
ECCN N (Not subject to export control regulations)
Country of Origin Germany (Estimated)

Installation Guidelines

CRITICAL WARNING: Disconnect all power sources and follow Lockout/Tagout (LOTO) procedures before installation or maintenance. Failure to de-energize the system can result in severe electrical shock, equipment damage, or personal injury.
  1. 1 Prepare the panel cutout according to the device's mechanical drawings. Ensure the mounting surface is clean, flat, and rigid enough to support the unit's weight.
  2. 2 Insert the Panel PC into the cutout from the front of the enclosure. Secure it from the rear using the provided mounting clamps, tightening them evenly to the manufacturer's specified torque to ensure a proper seal.
  3. 3 Connect the chassis to the cabinet's protective earth (PE) ground using a low-impedance conductor. A reliable ground connection is essential for electrical safety and noise immunity.
  4. 4 Connect the 24 VDC power supply to the designated terminals. Verify correct polarity (+/-) before applying power. Use appropriately sized wiring for the current draw.
  5. 5 Connect all required peripheral and communication cables (e.g., Ethernet, serial, USB). Ensure cables are routed away from high-voltage lines to minimize electromagnetic interference.

FAQ

What operating system is installed on the 6AV7615-0AB20-0AJ0?

This Panel PC comes pre-installed with Windows NT 4.0, English version.

What is the required input voltage for this Panel PC?

The unit requires a 24 V DC power supply.

What are the key hardware specifications?

It features a 15-inch TFT display, an Intel Celeron 300 MHz processor, 128 MB of RAM, a 20 GB hard drive, and a CD-ROM drive.

Is this a current product?

No, the 6AV7615-0AB20-0AJ0 is an obsolete product, primarily used for spare parts or maintaining existing legacy industrial systems.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.