This device is a Siemens 6AV7615-0AA10-0BF0, a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This standard configuration features a 15-inch TFT display, an Intel Celeron 300 MHz processor, 64 MB of RAM, and a 20 GB hard drive. The unit is pre-loaded with the Windows 98 operating system (English) and is powered by a 115-230V AC source via the included U.S. mains cable. As an obsolete component, it serves as a direct replacement for maintaining legacy automation systems.

Features

  • 15-inch TFT color display for process visualization
  • Intel Celeron 300 MHz processor
  • 64 MB of system RAM
  • 20 GB internal hard drive storage
  • Pre-installed with Windows 98 (English)
  • Includes a U.S. mains cable for 115-230V AC power sources

Applications

  • Human-Machine Interface (HMI) for process visualization
  • Machine control and data acquisition terminals
  • Industrial automation control rooms
  • Legacy manufacturing execution systems (MES)

Technical Specifications

Category Specification
General
Manufacturer Siemens
Product Series SIMATIC Panel PC 670
Part Number 6AV7615-0AA10-0BF0
Product Type Panel PC
Hardware
Display 15-inch TFT
Processor Celeron 300 MHz
Memory (RAM) 64 MB
Storage 20 GB Hard Drive (HD)
Software
Operating System Windows 98 (English)
Electrical
Input Power 115-230 V (via included U.S. mains cable)
Product Lifecycle
PLM Status Obsolete
Logistics
Shipping Weight 12.00 kg
Package Dimensions (Calculated) 35.0 x 25.0 x 25.0 cm
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimate)

Installation Guidelines

CRITICAL WARNING: HAZARDOUS VOLTAGE

Installation, wiring, and maintenance must be performed exclusively by qualified personnel. Failure to de-energize the system before service can result in severe injury or death. Always adhere to local lockout/tagout (LOTO) procedures.

  1. 1 De-energize the control cabinet and verify the absence of voltage before beginning installation.
  2. 2 Prepare the panel cutout according to the manufacturer's dimensional requirements. Ensure the mounting surface is clean, flat, and can support the weight of the unit.
  3. 3 Insert the Panel PC into the cutout and secure it evenly using all provided mounting clamps. Do not overtighten.
  4. 4 Connect a dedicated protective earth (PE) or chassis ground wire to the designated terminal on the unit's housing for safety and noise immunity.
  5. 5 Connect the provided 115-230V U.S. mains cable to a properly rated and protected power source.
  6. 6 After verifying all connections are secure, close the cabinet, re-apply power according to LOTO procedures, and perform initial boot checks.

FAQ

What operating system is installed on the 6AV7615-0AA10-0BF0?

This Panel PC comes pre-installed with the Windows 98 operating system in English.

What are the core hardware specifications?

The unit features an Intel Celeron 300 MHz processor, 64 MB of RAM, and a 20 GB hard drive.

What is the display size and type?

The device is equipped with a 15-inch TFT color display.

What is the required input voltage?

The panel PC operates on a 115-230V AC power source and includes a U.S. mains cable for connection.

Is this product still in production by Siemens?

No, the PLM (Product Lifecycle Management) status for this model is listed as Obsolete. It is available as a spare part for existing systems.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.