Siemens

Siemens 6AV7615-0AB22-0BF0 SIMATIC Panel PC 670 Panel PC

SKU 6AV7615-0AB22-0BF0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7615-0AB22-0BF0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 35.0 x 25.0 x 25.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This is a SIMATIC Panel PC 670 from Siemens, model 6AV7615-0AB22-0BF0, designed for industrial human-machine interface (HMI) and control applications. This standard configuration unit features a 15-inch TFT display, a Pentium III 500 MHz CPU, and 128 MB of RAM. It is equipped with a 20 GB hard drive and a CD-ROM drive for software installation and data access. The system is pre-loaded with the Windows 98 operating system (English) and is powered by a 115-230 V supply, with a U.S. mains cable included. Please note that this product is considered obsolete by the manufacturer, making it a critical spare part for maintaining legacy systems.

Features

  • 15-inch TFT color display for process visualization.
  • Powered by a Pentium III 500 MHz processor.
  • Equipped with 128 MB of system RAM.
  • Includes a 20 GB internal hard drive for storage.
  • Integrated CD-ROM drive for legacy media.
  • Pre-installed with Windows 98 (English).
  • Supports a wide input voltage range of 115-230 V.

Applications

  • Legacy machine control and automation systems.
  • Process visualization and data logging stations.
  • Factory floor operator interfaces (HMI).
  • Supervisory control and data acquisition (SCADA) nodes.

Technical Specifications

Specification Value
Manufacturer Siemens
Product Series SIMATIC Panel PC
Product Sub-range PC670
Model Number 6AV7615-0AB22-0BF0
Product Type Panel PC
Display 15-inch TFT
Processor (CPU) Pentium III, 500 MHz
Memory (RAM) 128 MB
Storage 20 GB Hard Drive (HD)
Optical Drive CD-ROM
Operating System Windows 98 (English)
Power Supply 115-230 V (U.S. mains cable included)
Product Lifecycle Status Obsolete
Shipping Weight 12.00 kg
Logistics Dimensions 35.0 x 25.0 x 25.0 cm
Commodity Code 85371091
Export Control (ECCN) N
Country of Origin Germany (Estimate)

Installation Guidelines

CRITICAL WARNING: Hazardous voltages are present within this equipment. All installation, maintenance, and troubleshooting activities must be performed by qualified personnel only. Failure to de-energize and lock out/tag out (LOTO) all power sources before servicing can result in severe injury or death.
  1. 1
    De-energize System: Before installation, ensure all power to the control cabinet is completely disconnected at the source. Verify the absence of voltage using a properly rated test instrument.
  2. 2
    Panel Mounting: Prepare the panel cutout according to the device's mechanical specifications. Secure the Panel PC into the cutout using all provided mounting clamps, ensuring they are tightened evenly to create a proper seal.
  3. 3
    Protective Grounding: Connect the chassis ground terminal to the main protective earth (PE) bus of the control cabinet using a low-impedance conductor. This is critical for both safety and noise immunity.
  4. 4
    Power Connection: Connect the provided mains cable to the unit's power input and a properly rated and protected power source (115-230 V). Ensure the power source is stable and within the specified range.
  5. 5
    Interface Cabling: Connect all required communication and I/O cables (e.g., Ethernet, serial, USB). Route cables away from high-voltage lines to minimize electrical noise interference.

FAQ

What processor is in this Panel PC?

The 6AV7615-0AB22-0BF0 is equipped with a Pentium III 500 MHz processor.

What is the pre-installed operating system?

The unit comes with Windows 98 (English edition) pre-installed.

What is the display size of this model?

This model features a 15-inch TFT display for HMI applications.

What is the required power supply voltage?

The panel PC operates on a 115-230 V supply and includes a U.S. mains cable.

Is this product still in production?

No, the 6AV7615-0AB22-0BF0 is an obsolete product, primarily available as a spare part for maintaining existing systems.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.