Siemens

Siemens 6AV7615-0AE10-0AE0 SIMATIC Panel PC 670

SKU 6AV7615-0AE10-0AE0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7615-0AE10-0AE0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 48 x 38 x 18 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This is a Siemens 6AV7615-0AE10-0AE0 SIMATIC Panel PC 670, an integrated human-machine interface (HMI) designed for industrial automation applications. This specific configuration features a 15-inch TFT display, a 300 MHz Celeron CPU, 64 MB of RAM, and a 40 GB hard drive. It operates on a 24 V DC power supply and comes pre-installed with a German-language version of the Windows 98 operating system. As an obsolete product, it serves as a critical spare part for maintaining legacy control systems.

Features

  • Integrated 15-inch TFT color display
  • Powered by a 300 MHz Celeron processor
  • Equipped with 64 MB of system RAM
  • Includes a 40 GB hard disk drive for storage
  • Designed for 24 V DC industrial power systems
  • Pre-loaded with Windows 98 (German)

Applications

  • Process visualization and control
  • Machine-level HMI for manufacturing lines
  • Data acquisition and logging
  • Maintenance of existing automation systems utilizing PC670 panels

Technical Specifications

Specification Value
Manufacturer Siemens
Model Number 6AV7615-0AE10-0AE0
Product Series SIMATIC Panel PC 670
Display 15-inch TFT
Processor Celeron 300 MHz
Memory (RAM) 64 MB
Storage 40 GB Hard Drive (HD)
Operating System Windows 98 (German)
Input Voltage 24 V DC
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N (Not subject to export control regulations)
Country of Origin Germany (Estimated)
Package Dimensions (Calculated) 48 x 38 x 18 cm

Installation Guidelines

CRITICAL WARNING: Electrical hazard. Disconnect all power sources before installation or maintenance. Work must be performed by qualified personnel only. Failure to comply can result in severe injury, death, or equipment damage.
  1. 1 Ensure the control cabinet is de-energized and locked out (LOTO) before beginning installation.
  2. 2 Verify the panel cutout dimensions match the PC 670's mounting requirements. Ensure the mounting surface is flat, clean, and provides a proper seal with the unit's gasket.
  3. 3 Secure the Panel PC into the cutout using the provided mounting clamps. Tighten clamps evenly to the manufacturer's specified torque to ensure a uniform seal and prevent bezel distortion.
  4. 4 Connect a dedicated chassis ground wire from the Panel PC's grounding stud to the main cabinet ground bus using a low-impedance connection.
  5. 5 Connect the 24 V DC power supply. Double-check polarity (+/-) before energizing the circuit. Use appropriately gauged wiring and ensure the power supply is stable and filtered.
  6. 6 Connect all required communication and I/O cables. Ensure proper shielding and grounding practices are followed to minimize electrical noise interference.

FAQ

What is the operating system on this panel PC?

This unit, model 6AV7615-0AE10-0AE0, comes pre-installed with a German-language version of Windows 98.

What is the required input voltage?

The SIMATIC Panel PC 670 requires a 24 V DC power supply for operation.

Is this a current Siemens product?

No, this product is classified as obsolete. It is primarily sourced as a spare part to maintain and repair existing industrial systems that use the PC 670 platform.

What are the memory and storage specifications for this configuration?

This specific configuration is equipped with 64 MB of RAM and a 40 GB hard disk drive (HD).

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...