Description

The Siemens 6AV7764-0AA00-0AT0 is an OEM-PC870 industrial touch panel computer from the SIMATIC family, engineered for machine control applications in demanding production environments. This unit is equipped with a 15-inch touchscreen, a Pentium III 1.2 GHz processor, and 512 MB of RAM. It is delivered without a pre-installed operating system or application software, offering a flexible platform for custom HMI configurations. The system includes a 20.4 GB hard drive and an LS240 floppy drive for legacy data compatibility, and is prepared for HMI-FO Link integration.

Features

  • 15-inch integrated touchscreen display
  • Pentium III processor operating at 1.2 GHz
  • 512 MB of installed RAM
  • 20.4 GByte internal hard drive for application and data storage
  • Integrated LS240 floppy drive for legacy media support
  • Supplied without an operating system for custom software deployment
  • Prepared for HMI-FO Link (Fiber Optic) integration

Applications

  • Human-Machine Interface (HMI) for industrial machinery
  • Process visualization and control systems
  • Data acquisition and logging in factory environments
  • Control panels for manufacturing and assembly lines
  • Integration into legacy automation systems requiring floppy disk support

Technical Specifications

Specification Value
Brand Siemens
Product Line SIMATIC
Model Number 6AV7764-0AA00-0AT0
Product Type OEM-PC870 Touch Panel
Display 15-inch Touchscreen
Processor Pentium III, 1.2 GHz
Memory (RAM) 512 MB
Storage 20.4 GByte Hard Drive
Removable Media LS240 Floppy Drive
Operating System Not included
Connectivity Prepared for HMI-FO Link
Product Lifecycle Status Obsolete
Commodity Code 85371091
ECCN N
Shipping Weight 22.00 kg
Package Dimensions (Calculated) 76 cm x 40 cm x 35 cm
Country of Origin Germany (Estimate)
Manufacturer Siemens

Installation Guidelines

CRITICAL WARNING: Hazardous voltages are present within industrial control panels. All installation, wiring, and maintenance must be performed by qualified personnel with all power sources locked out and tagged out (LOTO). Failure to de-energize equipment can result in severe injury or death.
  1. 1 De-energize the main control cabinet and verify the absence of voltage using a properly rated test instrument before beginning work.
  2. 2 Prepare the panel cutout according to the device's mechanical specifications. Ensure the mounting surface is clean, flat, and free of debris.
  3. 3 Insert the touch panel into the cutout from the front. Secure it from the rear using all provided mounting clamps, tightening them evenly to the manufacturer's recommended torque to ensure a proper seal.
  4. 4 Connect the main power supply wiring to the designated terminals. Use appropriately sized conductors and ensure polarity is correct.
  5. 5 Establish a low-impedance protective earth (PE) connection to the chassis ground stud. This is critical for operator safety and noise immunity.
  6. 6 Connect all necessary communication cables (e.g., Ethernet, serial, HMI-FO Link) and any peripheral devices. Ensure proper cable shielding and grounding practices are followed.
  7. 7 After a final inspection of all connections, close the cabinet door, remove the LOTO device, and re-energize the system for software installation and commissioning.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 7
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...