Siemens

Siemens 6AV7802-0BA12-1AC0 SIMATIC Panel PC 677 Panel PC

SKU 6AV7802-0BA12-1AC0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7802-0BA12-1AC0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371098

  • Payment: T/T, Western Union

  • Weight: 17g

  • Dimensions: 67.0 x 83.0 x 11.5 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7802-0BA12-1AC0 is a SIMATIC Panel PC 677 designed for industrial human-machine interface (HMI) and control applications. This unit features a 15-inch touch screen with a 1024x768 resolution, a front-accessible USB interface, and is powered by a Celeron M 370 processor. It is configured with 512 MB of DDR266 SDRAM and a redundant storage system consisting of two 60 GByte hard drives in a RAID configuration. The system comes pre-installed with Windows XP Professional and includes an integrated DVD-ROM drive.

Features

  • 15-inch touch-sensitive display with 1024x768 pixel resolution.
  • Powered by an Intel Celeron M 370 processor at 1.5 GHz.
  • Dual 60 GByte 2.5-inch hard drives configured for RAID.
  • Convenient front-side USB interface for peripheral access.
  • Integrated DVD-ROM optical drive.
  • Pre-installed with Windows XP Professional (Multi-User Interface).

Applications

  • Machine-level control and visualization
  • Process control and data acquisition systems
  • Factory automation and manufacturing execution systems (MES)
  • Industrial data logging and reporting stations

Technical Specifications

Specification Value
Brand Siemens
Model Number 6AV7802-0BA12-1AC0
Product Series SIMATIC Panel PC 677
Product Type Panel PC
Product Lifecycle Status Obsolete
Display Size 15 inch
Display Type Touch Screen
Resolution 1024 x 768 pixels
Processor Celeron M 370 / 1.5 GHz
Front Side Bus (FSB) 400 MHz
Cache 1 MB SLC
Memory (RAM) 512 MB DDR266 SDRAM (1x512MB)
Storage Dual Hard Disk Drive (2x 60 GByte, 2.5-inch) with RAID
Optical Drive DVD-ROM
Operating System Windows XP Professional MUI (EN, GE, FR, IT, SP, JP, CHN, KOR)
Interfaces Front side USB interface
Input Voltage 110-230V AC
Power Cable Europe
Shipping Weight 17.00 kg
Package Dimensions (Calculated) 67.0 x 83.0 x 11.5 cm
Commodity Code 85371098
ECCN N
Country of Origin Germany (Estimate)
Manufacturer Siemens

Installation Guidelines

CRITICAL WARNING: Disconnect all power sources before installation or maintenance. Failure to de-energize the equipment can result in severe electrical shock, injury, or death. Adhere to all local and national safety regulations, including Lockout/Tagout (LOTO) procedures.

  1. 1 Ensure the installation environment meets the specified operating conditions for temperature, humidity, and vibration.
  2. 2 Verify the panel cutout dimensions are correct before attempting to mount the unit. Secure the Panel PC into the cutout using all provided mounting clamps, tightening them evenly to ensure a proper seal.
  3. 3 Connect the protective earth (PE) terminal to the main system ground using a low-impedance conductor. A reliable ground connection is essential for safety and noise immunity.
  4. 4 Connect the AC power supply cable to a stable, correctly rated power source. Ensure the power cable is routed away from high-noise electrical lines.
  5. 5 Connect all required communication and peripheral cables (e.g., Ethernet, USB, serial). Secure all connections and provide strain relief for cables where necessary.

FAQ

What operating system is installed on the 6AV7802-0BA12-1AC0?

The unit is pre-installed with Windows XP Professional Multi-User Interface (MUI), supporting English, German, French, Italian, Spanish, Japanese, Chinese, and Korean languages.

What is the storage configuration of this Panel PC?

It is equipped with two 60 GByte, 2.5-inch hard disk drives configured in a RAID array for data redundancy or performance.

What are the display specifications?

This model features a 15-inch touch screen with a native resolution of 1024x768 pixels.

Does this unit have a front-panel USB port?

Yes, it is equipped with a front-side USB interface for convenient access to connect peripherals like keyboards, mice, or storage devices.

What is the required input power for this device?

The Panel PC operates on an AC power supply ranging from 110V to 230V.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.