Siemens

Siemens 6AV7820-0AB10-1AC0 SIMATIC Panel PC 577

SKU 6AV7820-0AB10-1AC0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7820-0AB10-1AC0

  • Country of origin:Germany

  • Product Type: PC Panels

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 15g

  • Dimensions: 64.0 x 64.0 x 42.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7820-0AB10-1AC0 is a SIMATIC Panel PC 577 designed for robust industrial computing and visualization tasks in demanding production environments. This unit integrates a 12-inch touch display for intuitive operator control and process monitoring. It is powered by an Intel Pentium 4 2.4 GHz processor and equipped with 512 MB DDR400 SDRAM, delivering reliable performance for machine control and HMI applications. The system includes an integrated DVD-ROM drive and comes pre-installed with Windows XP SP1 Professional MUI, offering multi-language support for global deployment.

Features

  • ■12-inch Touch-Sensitive Display
  • ■Intel Pentium 4 Processor at 2.4 GHz
  • ■512 MB DDR400 SDRAM
  • ■Integrated DVD-ROM Optical Drive
  • ■Pre-installed Windows XP SP1 Professional MUI
  • ■Multi-Language Support (EN, GE, FR, IT, SP, JP, CHN, KOR)

Applications

  • ■Human-Machine Interface (HMI) Stations
  • ■Production Line Monitoring and Control
  • ■Industrial Data Acquisition and Visualization
  • ■Machine-Level Control Systems

Technical Specifications

Specification Value
Manufacturer Siemens
Product Series SIMATIC Panel PC
Product Sub-Series PC577
Part Number 6AV7820-0AB10-1AC0
Display 12" Touch Display
Processor Pentium 4, 2.4 GHz
Memory (RAM) 512 MB DDR400 SDRAM
Optical Drive DVD-ROM
Operating System Windows XP SP1 Professional MUI
Product Lifecycle Phase Obsolete
Shipping Weight 15.00 kg
Package Dimensions (Calculated) 64.0 x 64.0 x 42.0 cm
Commodity Code 85371091
ECCN N
Country of Origin (Estimate) Germany

Installation Guidelines

CRITICAL WARNING: Hazardous voltages are present. All installation, wiring, and maintenance must be performed by qualified personnel only. Ensure the unit is de-energized and locked out/tagged out (LOTO) before accessing any terminals or internal components. Failure to comply can result in severe injury or death.
  1. 1 Panel Mounting: Prepare the panel cutout according to the device's mechanical drawings. Ensure the mounting surface is clean, flat, and rigid. Insert the Panel PC into the cutout and secure it evenly using all provided mounting clamps to maintain the specified ingress protection rating.
  2. 2 Power Connection: Connect the specified DC or AC power source to the designated power input terminals. Use appropriately sized conductors and ensure a secure connection. Verify the source voltage matches the rating on the device nameplate before applying power.
  3. 3 Protective Earth (PE) Grounding: Connect the designated protective earth terminal to the main system ground bus using a low-impedance conductor. This connection is critical for safety and for mitigating electromagnetic interference (EMI).
  4. 4 I/O and Communication Wiring: Connect all peripheral and network cables (e.g., Ethernet, USB, serial) to their respective ports. Route signal cables separately from high-voltage power cables to prevent noise coupling. Use shielded cables for communication links where specified.

FAQ

What processor is included in the 6AV7820-0AB10-1AC0?

This SIMATIC Panel PC is equipped with an Intel Pentium 4 processor operating at a clock speed of 2.4 GHz.

What operating system is pre-installed on this unit?

The unit comes with Windows XP SP1 Professional MUI (Multi-User Interface) pre-installed, which supports multiple languages including English, German, French, Italian, Spanish, Japanese, Chinese, and Korean.

How much memory does this Panel PC have?

The 6AV7820-0AB10-1AC0 is configured with 512 MB of DDR400 SDRAM.

What is the display size and type?

This model features a 12-inch color display with an integrated touch screen for operator input.

Is this product still in active production?

No, the 6AV7820-0AB10-1AC0 is listed with a product lifecycle phase of 'Obsolete'. It is available as a spare or replacement part.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.