Description

This is a Siemens 6AV7872-0AC30-0AC0 SIMATIC Panel PC 677B, an integrated human-machine interface (HMI) designed for industrial control and visualization applications. It features a 15-inch touchscreen display, an Intel Core 2 Duo T5500 1.66 GHz processor, and 2 GB of DDR2 RAM. Connectivity is provided through dual Gigabit Ethernet ports, multiple USB 2.0 interfaces, and an integrated PROFIBUS/MP port for field-level communication. The unit is configured with a 160 GB SATA hard drive and is pre-installed with the Windows XP Professional operating system.

Features

  • 15-inch touchscreen display with 1024 x 768 resolution
  • Intel Core 2 Duo T5500 processor operating at 1.66 GHz
  • 2 GB of DDR2 RAM for application processing
  • 160 GB SATA 3.5-inch hard disk drive for data storage
  • Dual 10/100/1000 Mbit/s Ethernet ports for network connectivity
  • Integrated PROFIBUS/MP interface for industrial communication
  • Four rear USB 2.0 ports and one front-side USB port for peripheral access
  • Two available PCI slots for system expansion
  • Operates on a 24 V DC power supply
  • Pre-installed with Windows XP Professional (Multi-User Interface)

Applications

  • Machine-level control and visualization
  • Data acquisition and logging systems
  • Process monitoring in manufacturing and production lines
  • PC-based automation control systems
  • Supervisory control and data acquisition (SCADA) nodes

Technical Specifications

Category Specification
General
Manufacturer Siemens
Product Series SIMATIC Panel PC 677B
Part Number 6AV7872-0AC30-0AC0
Product Lifecycle Obsolete
Display
Type Touchscreen
Size 15-inch
Resolution 1024 x 768 pixels
Processing
CPU Intel Core 2 Duo T5500
CPU Clock Speed 1.66 GHz
Memory (RAM) 2 GB DDR2
Buffered SRAM 2 MB
Storage
Type 3.5-inch SATA Hard Disk Drive (HDD)
Capacity 160 GB
Optical Drive Not included
Interfaces
Ethernet 2x 10/100/1000 Mbit/s
USB 4x USB 2.0 (rear), 1x USB (front)
Serial 1x COM1
Fieldbus PROFIBUS/MP
Expansion Slots 2x PCI
Electrical
Power Supply 24 V DC
Software
Operating System Windows XP Professional MUI (de, en, fr, es, it, ja, zh, ko)
Logistics and Trade
Shipping Weight 17.00 kg
Package Dimensions (Calculated) 67.0 cm x 83.0 cm x 11.5 cm
Commodity Code 85371098
ECCN N
Country of Origin Germany (Estimate)

Installation Guidelines

CRITICAL WARNING: RISK OF ELECTRIC SHOCK AND EQUIPMENT DAMAGE

This equipment must be installed and serviced by qualified personnel only. Disconnect all power sources before installation or maintenance. Failure to observe this precaution can result in severe injury or death. Ensure the unit is properly grounded according to local electrical codes.

  1. 1 De-energize the control cabinet and implement lock-out/tag-out (LOTO) procedures before beginning installation.
  2. 2 Verify the panel cutout dimensions match the Panel PC's mounting requirements. Ensure the mounting surface is clean, flat, and free of debris.
  3. 3 Insert the Panel PC into the cutout and secure it evenly using all provided mounting clamps. Do not over-tighten the clamps to avoid deforming the bezel.
  4. 4 Connect a dedicated protective earth (PE) or functional ground wire to the chassis grounding terminal. A low-impedance ground connection is essential for noise immunity and safety.
  5. 5 Connect the 24 V DC power supply, ensuring correct polarity is observed. Use appropriately sized conductors for the load and distance from the power supply.
  6. 6 Connect Ethernet, PROFIBUS, USB, and any other required communication or peripheral cables. Route cables to minimize strain and avoid interference from high-power lines.
  7. 7 After verifying all connections, remove LOTO devices and re-energize the cabinet. Power on the Panel PC and confirm that the operating system boots correctly.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.